Hi Bruce,

I used this parameter in the ar.cfg file when one of my user complained
about not being able to access menus and data from table fields.
This was one off case where only he was receiving either

1) ARERR [552] Failure during SQL operation to the database : Invalid column
name 'C200000006'.

AND/OR

2) ARWARN [311] Field ID is not related to this form : 200000006
After a little research into the various workflow components causing
this error, I found that there were multiple AR server-name formats
available (i.e. server long name, short name and IP address) for selecting
the same server name to either build SQL menu or defining a table within
Table property tab. Because of this inconsistency, the server name was not
being resolved correctly hence the errors.

Adding server alias and IP Name parameter fixed the issue as (Axton was
mentioning) it was able to resolve server names within the workflow
definitions correctly.

thanks,
-Srinivas M.

On Fri, May 7, 2010 at 7:10 AM, Bruce Sisk <[email protected]> wrote:

> Good morning,
>
> Last night I added the IP Name parameter to my ar.cfg file.  It seems to be
> ok on the client tool, but I am having a problem now logging into the admin
> tool.
>
> who has used this parameter?  did it help??
>
> any input would be appreciated
>
> bruce
>
> ________________________________________
> PeoplePC Online
> A better way to Internet
> http://www.peoplepc.com
>
>
> _______________________________________________________________________________
> UNSUBSCRIBE or access ARSlist Archives at www.arslist.org
> attend wwrug10 www.wwrug.com ARSlist: "Where the Answers Are"
>

_______________________________________________________________________________
UNSUBSCRIBE or access ARSlist Archives at www.arslist.org
attend wwrug10 www.wwrug.com ARSlist: "Where the Answers Are"

Reply via email to