Dear All, Hope you are doing good.
I have a problem where OOB filter that does the notify action is firing, but no record is getting created on AR System Email Messages form. below is an extract of the log: Checking "NTE:NTS:Email_200_SystemNT" <FLTR> <TID: 0000004776> <RPC ID: 0000002168> <Queue: Escalation> <Client-RPC: 390603 > <USER: AR_ESCALATOR > <Overlay-Group: 1 > 0: Notify <FLTR> <TID: 0000004776> <RPC ID: 0000002168> <Queue: Escalation> <Client-RPC: 390603 > <USER: AR_ESCALATOR > <Overlay-Group: 1 > Priority: 0 Mechanism: Email To: [email protected] <FLTR> <TID: 0000004776> <RPC ID: 0000002168> <Queue: Escalation> <Client-RPC: 390603 > <USER: AR_ESCALATOR > <Overlay-Group: 1 > Your group has been assigned for Work Order WO0000000000603 as Assignee group. Please review the request. Priority: Low Summary: test please ignore <FLTR> <TID: 0000004776> <RPC ID: 0000002168> <Queue: Escalation> <Client-RPC: 390603 > <USER: AR_ESCALATOR > <Overlay-Group: 1 > Your group has been assigned for Work Order WO0000000000603 as Assignee group. Please review the request. <FLTR> <TID: 0000004776> <RPC ID: 0000002168> <Queue: Escalation> <Client-RPC: 390603 > <USER: AR_ESCALATOR > <Overlay-Group: 1 > /* Tue Apr 23 2013 11:54:43.0680 */ Start filter processing (phase 1) -- Operation - CREATE on AR System Email Attachments - <NULL> <FLTR> <TID: 0000004776> <RPC ID: 0000002168> <Queue: Escalation> <Client-RPC: 390603 > <USER: AR_ESCALATOR > <Overlay-Group: 1 > /* Tue Apr 23 2013 11:54:43.0680 */ <Filter Level:0 Number Of Filters:0> Checking "AR System Email GUID Generator" (500) <FLTR> <TID: 0000004776> <RPC ID: 0000002168> <Queue: Escalation> <Client-RPC: 390603 > <USER: AR_ESCALATOR > <Overlay-Group: 1 > --> Failed qualification <FLTR> <TID: 0000004776> <RPC ID: 0000002168> <Queue: Escalation> <Client-RPC: 390603 > <USER: AR_ESCALATOR > <Overlay-Group: 1 > /* Tue Apr 23 2013 11:54:43.0680 */ <Filter Level:0 Number Of Filters:1> Checking "AR System Email Attachments Update Reference" (1000) <FLTR> <TID: 0000004776> <RPC ID: 0000002168> <Queue: Escalation> <Client-RPC: 390603 > <USER: AR_ESCALATOR > <Overlay-Group: 1 > --> Passed -- perform actions <FLTR> <TID: 0000004776> <RPC ID: 0000002168> <Queue: Escalation> <Client-RPC: 390603 > <USER: AR_ESCALATOR > <Overlay-Group: 1 > 0: Set Fields <FLTR> <TID: 0000004776> <RPC ID: 0000002168> <Queue: Escalation> <Client-RPC: 390603 > <USER: AR_ESCALATOR > <Overlay-Group: 1 > Reference Count (18254) = 0 <FLTR> <TID: 0000004776> <RPC ID: 0000002168> <Queue: Escalation> <Client-RPC: 390603 > <USER: AR_ESCALATOR > <Overlay-Group: 1 > Temp Name (18248) = <FLTR> <TID: 0000004776> <RPC ID: 0000002168> <Queue: Escalation> <Client-RPC: 390603 > <USER: AR_ESCALATOR > <Overlay-Group: 1 > /* Tue Apr 23 2013 11:54:43.0690 */ End of filter processing (phase 1) -- Operation - CREATE on AR System Email Attachments - <NULL> <FLTR> <TID: 0000004776> <RPC ID: 0000002168> <Queue: Escalation> <Client-RPC: 390603 > <USER: AR_ESCALATOR > <Overlay-Group: 1 > /* Tue Apr 23 2013 11:54:43.0960 */ End of filter processing (phase 3) on NTE:Notifier - NTS000000003017 <FLTR> <TID: 0000004776> <RPC ID: 0000002168> <Queue: Escalation> <Client-RPC: 390603 > <USER: AR_ESCALATOR > <Overlay-Group: 1 > /* Tue Apr 23 2013 11:54:43.0960 */ Restart of filter processing (phase 3) on NTE:Notifier - NTS000000003018 <FLTR> <TID: 0000004776> <RPC ID: 0000002168> <Queue: Escalation> <Client-RPC: 390603 > <USER: AR_ESCALATOR > <Overlay-Group: 1 > /* Tue Apr 23 2013 11:54:43.0970 */ <Filter Level:0 Number Of Filters:542> Checking "NTE:NTS:Email_200_SystemNT" I was expecting post creation of record on AR System Email Attachments, it would create a record of Creation on AR System Email mesages form(THis is how a working system's log shows up) System: ARS 7.6.04 SP4 on Windows Server 2008 R2, -- - Karthik _______________________________________________________________________________ UNSUBSCRIBE or access ARSlist Archives at www.arslist.org "Where the Answers Are, and have been for 20 years"