Guys, Thanks for your valuable input. Have fixed this issue. :)
Regards, Suresh Loganathan. On Apr 25, 2014 6:38 AM, "Michelle Grace" <[email protected]> wrote: > My in progress issue with DMT was the system was looking for FQDN and not > short name. Then I had an issue with > Jobs in the Data Management > Job Console ran and validate but never > promoted. > > Fix > > 1. Disable all logs (ensure no logs are on). > 2. Search for records with 'Parent_Job_GUID' = "DO NOT REMOVE" in > form DMT:SYS:SequencingEngine and delete all matching records from the form. > 3. Open form DMT:SYS:StagingFormDependency in search mode (blank > search screen) and then click the button Rebuild Sequence Table > 4. Wait for a few minutes (around 5-10 minutes) and then query form > DMT:SYS:SequencingEngine and see if you have records with values with 'GO' > prefix in data in field Stream (304302140) > > Hope this helps > > Michelle > > > _______________________________________________________________________________ > UNSUBSCRIBE or access ARSlist Archives at www.arslist.org > "Where the Answers Are, and have been for 20 years" > _______________________________________________________________________________ UNSUBSCRIBE or access ARSlist Archives at www.arslist.org "Where the Answers Are, and have been for 20 years"