Guys,

Thanks for your valuable input. Have fixed this issue. :)

Regards,

Suresh Loganathan.
On Apr 25, 2014 6:38 AM, "Michelle Grace" <[email protected]> wrote:

> My in progress issue with DMT was the system was looking for FQDN and not
> short name. Then I had an issue with
> Jobs in the Data Management > Job Console ran and validate but never
> promoted.
>
> Fix
>
> 1.      Disable all logs (ensure no logs are on).
> 2.      Search for records with 'Parent_Job_GUID' = "DO NOT REMOVE" in
> form DMT:SYS:SequencingEngine and delete all matching records from the form.
> 3.      Open form DMT:SYS:StagingFormDependency in search mode (blank
> search screen) and then click the button Rebuild Sequence Table
> 4.      Wait for a few minutes (around 5-10 minutes) and then query form
> DMT:SYS:SequencingEngine and see if you have records with values with 'GO'
> prefix in data in field Stream (304302140)
>
> Hope this helps
>
> Michelle
>
>
> _______________________________________________________________________________
> UNSUBSCRIBE or access ARSlist Archives at www.arslist.org
> "Where the Answers Are, and have been for 20 years"
>

_______________________________________________________________________________
UNSUBSCRIBE or access ARSlist Archives at www.arslist.org
"Where the Answers Are, and have been for 20 years"

Reply via email to