> I want to doubly make sure, that
> 
> If I understood correctly,
> 
> Even for PER, Un-aligned, if the data length is crossing
> 64K units, and
> 
> L(min) = L(max) 
> 
> the LENGTH encoding is done.
> (This also true for PER, Aligned case too.)

Yes, that's correct. I checked it with asn1step to be sure.

> Note that the size constraint is forcing trailing 0's to be encoded.
> If you were to leave off the size constraint, a length determinant would 
> become necessary, but the string of all 0's would become a null string.

However, my statement above is not correct for all cases. It applies
only when there's a NamedBitList.

=====================================================================
Conrad Sigona                         Toll Free      : 1-888-OSS-ASN1  
OSS Nokalva                           Voice Mail     : 1-732-302-9669 x400  
[EMAIL PROTECTED]                        Fax            : 1-419-831-5035
http://www.oss.com                    My direct line : 1-315-845-1773