> Theirs > -------------------------------- > 66 82 02 49 7F 81 6A > > Mine > --------------------------------- > 66 85 20 7F 81 6A > > Both - 66 Is the TAG , being a COMPOSITE APPLICATION TAG 6 > Theirs - 82 02 49 - 82 02 should be the LENGTH portion but it's not big > enough and 49 > is nothing at all > Mine - 85 20 is the LENGTH > Both - 7F 81 6A is a composite tag inside the current TAG (ie Data > Portion)
If you are truly showing the start of the PDU, the length field is 820249, which says 1xxx xxxx long length x000 0010 the length is 2 octets long 0249 the length is 585. Yours therefore has an incorrect length field. ===================================================================== Conrad Sigona Toll Free : 1-888-OSS-ASN1 OSS Nokalva Voice Mail : 1-732-302-9669 x400 [EMAIL PROTECTED] Fax : 1-419-831-5035 http://www.oss.com My direct line : 1-315-845-1773