I think I may be missing something here, but I can't
pin it down.

Program A contains DCB/DCBE for a file; the DCBE has
  EODAD=ENDIFILE

The routine called ENDIFILE contains just this:

   oiy   flags,endInfile
   br    r14




Program A opens the file and later links (linkx) to
Program B, passing the dcb; Program B does GETs;
after each GET, Program B checkd if the end of file
flag is set.


I have verified that both programs are accessing the
same byte / bit and that the end of file flag is, indeed,
set.


But, control does _not_ return to PROGRAM B from the
EODAD routine in PROGRAM A. Instead I get

IEC020I 001-5,TESTF005,STEP1,TTFIN,0D30,VPWRKA,
IEC020I SCOMSTO.B625.NEW.FOLKS
IEC020I GET ISSUED AFTER END-OF-FILE           <===

and an abend.

All the reading I've done seems to indicate my logic
is viable, but it's not working.

Any suggestions?


--

Kind regards,

-Steve Comstock
The Trainer's Friend, Inc.

303-355-2752
http://www.trainersfriend.com