On 17 May 2012 21:05, robin <[email protected]> wrote: > They are no substitute for > > MVC A(L'B-1),B
Several people have posted things like this with a "length-1". I'm curious why people feel the need to do what the assembler does for them, and wind up a byte short. Of course it's correct if you are composing your own instruction using DCs, but not in an MVC. Unless perhaps you are dealing with some evil Cism... Tony H.
