Jim,

    I saw that in the manual.  So, if I am running in problem state,
Key 8,  can I update the SDWA before executing the SETRP?

     --Dave
On 6/25/2012 5:25 PM, Jim Mulder wrote:
      I am in the process of moving some data areas above the bar.  Is
there a way to update registers for retry specifying a 64 bit register
value?  I don't see this in the fine manual.  Am I missing something
obvious?
   RUB is not applicable to 64-bit registers.  The manual says:

If you are running in z/Architecture mode and specify
RETREGS=64, the 64-bit GPRs at retry are restored from
SDWAG64 and the ARs are restored from SDWAARSV.


Jim Mulder   z/OS System Test   IBM Corp.  Poughkeepsie,  NY

Reply via email to