Include DFHEIA0 as the first CSECT in the load module.

On Fri, 27 Jul 2012 10:27:26 -0400 Mainframe Mainframe
<[email protected]> wrote:

:>I'm trying to make a little CICS Assembler program an I get always a 0C4 at
:>execution. DFHSR0618 CICSPROD An illegal macro call or reference to the CSA
:>or TCA. Here's my program.
:>
:>SETOPTI  CSECT
:>         STM   R14,R12,12(R13)    * SAVE CALLER'S REGS
:>         USING SETOPTI,R12              * R12 IS BASE
:>         ST    R13,SAVEAREA+4
:>         LA    R13,SAVEAREA
:>         B     STARTUP
:>*
:>         DC    CL8'SETOPTI'
:>         DC    C'&SYSDATE'
:>         DC
:>C'&SYSTIME'
:>
:>STARTUP  DS    0H
:>         EXEC CICS ASKTIME
:>***********************************************************
:>*
:>RETOUR   DS    0H
:>         DFHEIRET
:>
:>Does someone can help me.

--
Binyamin Dissen <[email protected]>
http://www.dissensoftware.com

Director, Dissen Software, Bar & Grill - Israel


Should you use the mailblocks package and expect a response from me,
you should preauthorize the dissensoftware.com domain.

I very rarely bother responding to challenge/response systems,
especially those from irresponsible companies.

Reply via email to