Lock me up when I say that consistent layout of documentation does not matter... ;-)
I was reading SA23-2261-02 trying to make sense of the CPU MF counters. And looking at Page 5 which has the heading "The CPU-Measurement Facility Extended Counters Definition for z10,z196/z114,zEC12" and lists counters 128-135 and it just did not match the numbers I see. Turns out that heading is the name of the book rather than the chapter. This particular page only applies to the z10 as indicated by the :h2 on the previous page. The counters for the z196 (which I wanted) are on Page 7 with the same heading as Page 5. And they are pretty different. Sigh. Rob