think we have that issue id'd .. will repost on ibm main... still have problems...and understanding linkng all together once loaded down...maybe missing a parameter...reading manual and so far---nada
From: Lizette Koehler <[email protected]> To: [email protected] Date: 10/08/2015 10:38 AM Subject: Re: DFDSS Sent by: IBM Mainframe Assembler List <[email protected]> I think if you focus on this part of your output REQPRI=0000061500TRK REQSEC=0000000750CYL You can see if you have sufficient space on the volume You may need to use OUTDD statements if you are not using SMS to manage this file. Lizette > -----Original Message----- > From: IBM Mainframe Assembler List [ mailto:[email protected]] > On Behalf Of Ron Wells > Sent: Thursday, October 08, 2015 8:23 AM > To: [email protected] > Subject: Re: DFDSS > > to make this clear.. > Multi volume dataset... > trying to extract and restore from a full vol backup. > > > > From: Ron Wells/AGFS/AGFin > To: IBM Mainframe Assembler List <[email protected]> > Date: 10/08/2015 09:51 AM > Subject: DFDSS > > > trying to do a restore of a dataset that is ..Multi-Volume disk > > See below...jcl and error... > > //DFDSS EXEC PGM=ADRDSSU ,PARM='TYPRUN=NORUN' > > //TAPE DD DSN=SYS4.VSYT033.FULLVOL.BKUP(+0),DISP=SHR > > > //SYSPRINT DD SYSOUT=* > > //SYSIN DD * > > RESTORE INDDNAME(TAPE) OUTDYNAM((TMP001),(TMP002),(TMP003)) - > DATASET( - > INCLUDE( - > OEM.AGFT.ASGVD664.TOPICOPY.EIXSTAGE - >>>> dataset > restoring from full vol backup > )) - > SPHERE TOL(ENQF) > > ERROR > > ADR101I (R/I)-RI01 (01), TASKID 001 HAS BEEN ASSIGNED TO COMMAND 'RESTORE ' > ADR109I (R/I)-RI01 (01), 2015.281 09:41:32 INITIAL SCAN OF USER CONTROL > STATEMENTS COMPLETED > ADR016I (001)-PRIME(01), RACF LOGGING OPTION IN EFFECT FOR THIS TASK > > ADR006I (001)-STEND(01), 2015.281 09:41:32 EXECUTION BEGINS > ADR780I (001)-TDDS (01), THE INPUT DUMP DATA SET BEING PROCESSED IS IN FULL > VOLUME FORMAT AND WAS CREATED BY DFSMSDSS VERSION 1 > RELEASE 13 MODIFICATION LEVEL 0 ON 2015.276 > 19:13:14 > ADR709E (001)-VDSS (01), AN ERROR OCCURRED IN THE STORAGE MANAGEMENT > SUBSYSTEM WHILE ALLOCATING DATA SET > OEM.AGFT.ASGVD664.TOPICOPY.EIXSTAGE. SMS MESSAGES FOLLOW. > IGD17365I EXTENT REDUCTION FAILED FOR DATA SET > OEM.AGFT.ASGVD664.TOPICOPY.EIXSTAGE > ADR809I (001)-VDSS (01), ADDITIONAL DIAGNOSTIC DATA FOR PRECEDING > MESSAGE: > > SC= MC= DC= > REQPRI=0000061500TRK REQSEC=0000000750CYL > REQVOLS=01 > ADR382W (001)-TDDS (01), THE FOLLOWING DATA SETS WERE NOT PROCESSED > FROM VOLUME SYT037 DUE TO ERRORS > OEM.AGFT.ASGVD664.TOPICOPY.EIXSTAGE > ADR415W (001)-TDDS (01), NO DATA SETS WERE COPIED, DUMPED, OR RESTORED > FROM LOGICALVOLUME SYT037 ADR423W (001)-TDDS (01), SELECTED DATA SET > OEM.AGFT.ASGVD664.TOPICOPY.EIXSTAGE IS A MULTIVOLUME DATA SET ADR415W > (001)-TDDS (02), NO DATA SETS WERE COPIED, DUMPED, OR RESTORED FROM ANY > VOLUME > ADR006I (001)-STEND(02), 2015.281 09:41:32 EXECUTION ENDS > ADR013I (001)-CLTSK(01), 2015.281 09:41:32 TASK COMPLETED WITH RETURN > CODE > 0008 > ADR012I (SCH)-DSSU (01), 2015.281 09:41:32 DFSMSDSS PROCESSING COMPLETE. > HIGHEST RETURN CODE IS 0008 FROM: > TASK 001 > ---------------------------------------------------------------------- Email Disclaimer This E-mail contains confidential information belonging to the sender, which may be legally privileged information. This information is intended only for the use of the individual or entity addressed above. If you are not the intended recipient, or an employee or agent responsible for delivering it to the intended recipient, you are hereby notified that any disclosure, copying, distribution, or the taking of any action in reliance on the contents of the E-mail or attached files is strictly prohibited.