Perfect! Thanks,

Charles


-----Original Message-----
From: IBM Mainframe Assembler List [mailto:[email protected]]
On Behalf Of Jonathan Scott
Sent: Thursday, August 17, 2017 10:15 AM
To: [email protected]
Subject: Re: Source address significance for clearing MVCL

Ref:  Your note of 17 August 2017, 09:00:52 EDT

It is there in the book (SA22-7832-09, second sentence in the last paragraph
before the Resulting Condition Code heading):

  When the length of an operand is zero, no access exceptions for that
  operand are recognized.

Charles Mills wrote:
> I don't see this explicitly in the PoOp. Is my recollection correct? 
> That for a "pure clearing" MVCL (source length zero, destination 
> length non-zero) the contents of source address register R2 are not 
> significant, and a specification or access exception on the source address
is not possible?

Jonathan Scott
HLASM
IBM UK Labs, Hursley

Reply via email to