? IKJ57280I R6SAVE NOT IN INTERNAL SYMBOL TABLE FOR PDS86 . PDSMAIN On Mon, Mar 11, 2019 at 11:32 AM Tony Harminc <[email protected]> wrote:
> On Mon, 11 Mar 2019 at 11:49, Janko Kalinic <[email protected]> > wrote: > > > test 'ad.cmdlib(pds86)' cp > > IKJ57090A ENTER COMMAND FOR CP > > xispmode > > TEST > > at pds86.pdsinit.initaddr > > TEST > > equate workarea 7r% > > Where is R7 pointing at this point? You haven't executed any of your > code yet, it appears. EQUATE doesn't save symbolic names and resolve > them later; it will use the value of R7 at the time you issue the > EQUATE subcommand. > > > TEST > > go > > IKJ57024I AT PDS86.PDSINIT.INITADDR > > TEST > > l workarea > > WORKAREA 00A7F400 > > TEST > > l r6save > > IKJ57280I ADDRESS R6SAVE NOT FOUND+ > > IKJ56703A REENTER THIS OPERAND - > > You didn't enter a ? to get the second level message. It could be > something like "address is in protected storage". > > Tony H. >