"IBM Mainframe Assembler List" <ASSEMBLER-LIST@LISTSERV.UGA.EDU> wrote on 
02/14/2022 12:05:20 PM:
> I would consider using TP to verify the signs and protect yourself from 
> S0C7 on the subsequent handling of the packed number

        Why would I get S0C7 due to an invalid sign when I'm using PKA 
(not PACK) which ignores the original sign altogether and forces a 
standard positive sign on output?


> I would not do anything against the number (no MHI or so)

        Why not?


> - just EDMK it and place the sign(depending on the results of the 
> previous tests) where ever it needs to be.

        I can't do that because I'm using a generic, reusable routine to 
convert binary to zoned and it can't see the original record data.  It 
only sees the data I pass to it in a 64-bit register.  So the passed data 
has to already have the correct sign.


Sincerely,

Dave Clark
-- 
int.ext: 91078
direct: (937) 531-6378
home: (937) 751-3300

Winsupply Group Services
3110 Kettering Boulevard
Dayton, Ohio  45439  USA
(937) 294-5331




*********************************************************************************************
This email message and any attachments is for use only by the named 
addressee(s) and may contain confidential, privileged and/or proprietary 
information. If you have received this message in error, please 
immediately notify the sender and delete and destroy the message and all 
copies. All unauthorized direct or indirect use or disclosure of this 
message is strictly prohibited. No right to confidentiality or privilege 
is waived or lost by any error in transmission. 
*********************************************************************************************