Hi,
I'm testing IEFU86 exit to be able to write on syslog the SMF record number on 
the fly. 
It's just for educational purpose.

When I use the workarea (retrieved from IFAEXITP) to store my WTO, SMF 
record,etc it works pretty well.
I am able to WTO the SMF records number in syslog. 
But when I login/logoff, it fails with S0C4-11 (I don't use getmain/freemain 
storage obtain/release in my code).

When I use STORAGE OBTAIN/release to store my stuffs and don't use IEFU86 
workarea, it works well. No more S0C4-11 when I login/logoff.

According to this thread :

 
https://bit.listserv.ibm-main.narkive.com/cIdJ48RP/smf-exit-iefu086-work-area-size#post16

the workarea seems shared (maybe why it fails for me ?) If it is the case, what 
is the utility of the workarea ?

Thank you for your help
Guillaume

Reply via email to