By default the bays and HMM valence values are set to 49 and 55
(regular and local); now... according to the interface if one enables
both checks (setting them to score), the values should be revised...
the problem is that it's unclear how to set them; I mean, if I read the
GUI it says

"for this reason it is recommended to use both Bayesian and HMM. If you
enable both checks, check your settings for baysValencePB,
HMMValencePB, bayslocalValencePB and HMMlocalValencePB - eg. divide
them by 2. or set the bayes values to 1/3 and the HMM values to 2/3."

now... following the above one would set values to (say) 24 and 27 (or
25 and 28) but... is this correct ? Also, I tried enabling HMM (that
is setting it to "score") and then running a rebuild to ensure its table
was correctly populated but even then, ASSP logged messages like this

"HMM-Check has given less than 6 results - using monitoring mode only"

and while I can't understand the above (ok, probably I'm just dumb) the
above means that HMM won't score the message so I'd be left running on
bayes and since I changed bayes to 24, some spam could get through...

Bottom line; what's the correct way (step by step) to enable HMM, how
to correctly set the valence(s) and... what does that "less than..."
message mean ?


------------------------------------------------------------------------------
WatchGuard Dimension instantly turns raw network data into actionable 
security intelligence. It gives you real-time visual feedback on key
security issues and trends.  Skip the complicated setup - simply import
a virtual appliance and go from zero to informed in seconds.
http://pubads.g.doubleclick.net/gampad/clk?id=123612991&iu=/4140/ostg.clktrk
_______________________________________________
Assp-test mailing list
[email protected]
https://lists.sourceforge.net/lists/listinfo/assp-test

Reply via email to