On Fri, May 10, 2013 at 11:34 AM, Irek Szczesniak <[email protected]> wrote:
> Assigning a value to a bool via a discipline doesn't check for invalid values.
>
> This example should IMO throw a  ksh: _Bool: b:  invalid value 300000 error:
> ksh -c 'bool b=false ; b.get() { .sh.value=300000 ; } ; print -- $b'
> 300000

Issue is still present in AJM 93v- 2013-05-22

Irek
_______________________________________________
ast-developers mailing list
[email protected]
http://lists.research.att.com/mailman/listinfo/ast-developers

Reply via email to