On Fri, May 10, 2013 at 11:34 AM, Irek Szczesniak <[email protected]> wrote: > Assigning a value to a bool via a discipline doesn't check for invalid values. > > This example should IMO throw a ksh: _Bool: b: invalid value 300000 error: > ksh -c 'bool b=false ; b.get() { .sh.value=300000 ; } ; print -- $b' > 300000
Issue is still present in AJM 93v- 2013-05-22 Irek _______________________________________________ ast-developers mailing list [email protected] http://lists.research.att.com/mailman/listinfo/ast-developers