hi all

setting CALLERID(rdnis) works well between two asterisk boxes, but I can't make this work when talking to the telco's switch. They sent me a trace done from the link, connected between the * box and their switch, and it looks like asterisk may be sending something the wrong way here, or am I mistaken?

Please take a look at the trace attached, line 272 and below

thanks

roy
---
Roy Sigurd Karlsbakk
[EMAIL PROTECTED]
---------------------------------
Those people who think they know everything are a great annoyance to those of us who do. (Isaac Asimov)

Attachment: X00000.TXT
Description: application/applefile

LU1 mot Briz SLink1   00:07.074 
  === LAPD ===
   --- ADDRESS ---
   SAPI       : 0 = call control procedures
   CR         : ......0.
   EA0        : .......0
   TEI        : 0 = non-automatic TEI assignment user equipment
   EA1        : .......1
   --- CONTROL ---
   --- S FRAME ---
   S FORMAT   : ......01
   SFB        : ....00.. = RR (receive ready)
   P/F        : .......1
   N(R)       : 47
LU1 mot switch SLink1 00:07.079 
  === LAPD ===
   --- ADDRESS ---
   SAPI       : 0 = call control procedures
   CR         : ......0.
   EA0        : .......0
   TEI        : 0 = non-automatic TEI assignment user equipment
   EA1        : .......1
   --- CONTROL ---
   --- S FRAME ---
   S FORMAT   : ......01
   SFB        : ....00.. = RR (receive ready)
   P/F        : .......1
   N(R)       : 30
LU1 mot Briz SLink1   00:17.077 
  === LAPD ===
   --- ADDRESS ---
   SAPI       : 0 = call control procedures
   CR         : ......0.
   EA0        : .......0
   TEI        : 0 = non-automatic TEI assignment user equipment
   EA1        : .......1
   --- CONTROL ---
   --- S FRAME ---
   S FORMAT   : ......01
   SFB        : ....00.. = RR (receive ready)
   P/F        : .......1
   N(R)       : 47
LU1 mot switch SLink1 00:17.082 
  === LAPD ===
   --- ADDRESS ---
   SAPI       : 0 = call control procedures
   CR         : ......0.
   EA0        : .......0
   TEI        : 0 = non-automatic TEI assignment user equipment
   EA1        : .......1
   --- CONTROL ---
   --- S FRAME ---
   S FORMAT   : ......01
   SFB        : ....00.. = RR (receive ready)
   P/F        : .......1
   N(R)       : 30
LU1 mot Briz SLink1   00:17.258 
  === LAPD ===
   --- ADDRESS ---
   SAPI       : 0 = call control procedures
   CR         : ......0.
   EA0        : .......0
   TEI        : 0 = non-automatic TEI assignment user equipment
   EA1        : .......1
   --- CONTROL ---
   --- I FRAME ---
   I FORMAT   : .......0
   N(S)       : 30
   P          : .......0
   N(R)       : 47
   === ETSI ISDN ===
    PROT DISC  : 08h = Q.931 user-network call control message
    LEN CALL R : 2
    CALL REF   : 25
    MESS TYPE  : 45h = Disconnect
    --- DISCONNECT ---
     --- CAUSE ---
     CODING STD : .00..... = CCITT standardized coding
     LOCATION   : ....0001 = private network serving the local user
     CAUSE VAL  : .0010000 = normal call clearing
LU1 mot switch SLink1 00:17.263 
  === LAPD ===
   --- ADDRESS ---
   SAPI       : 0 = call control procedures
   CR         : ......0.
   EA0        : .......0
   TEI        : 0 = non-automatic TEI assignment user equipment
   EA1        : .......1
   --- CONTROL ---
   --- S FRAME ---
   S FORMAT   : ......01
   SFB        : ....00.. = RR (receive ready)
   P/F        : .......0
   N(R)       : 31
LU1 mot switch SLink1 00:17.582 
  === LAPD ===
   --- ADDRESS ---
   SAPI       : 0 = call control procedures
   CR         : ......1.
   EA0        : .......0
   TEI        : 0 = non-automatic TEI assignment user equipment
   EA1        : .......1
   --- CONTROL ---
   --- I FRAME ---
   I FORMAT   : .......0
   N(S)       : 47
   P          : .......0
   N(R)       : 31
   === ETSI ISDN ===
    PROT DISC  : 08h = Q.931 user-network call control message
    LEN CALL R : 2
    CALL REF   : 25
    MESS TYPE  : 4Dh = Release
    --- RELEASE ---
LU1 mot Briz SLink1   00:17.583 
  === LAPD ===
   --- ADDRESS ---
   SAPI       : 0 = call control procedures
   CR         : ......1.
   EA0        : .......0
   TEI        : 0 = non-automatic TEI assignment user equipment
   EA1        : .......1
   --- CONTROL ---
   --- S FRAME ---
   S FORMAT   : ......01
   SFB        : ....00.. = RR (receive ready)
   P/F        : .......0
   N(R)       : 48
LU1 mot Briz SLink1   00:17.585 
  === LAPD ===
   --- ADDRESS ---
   SAPI       : 0 = call control procedures
   CR         : ......0.
   EA0        : .......0
   TEI        : 0 = non-automatic TEI assignment user equipment
   EA1        : .......1
   --- CONTROL ---
   --- I FRAME ---
   I FORMAT   : .......0
   N(S)       : 31
   P          : .......0
   N(R)       : 48
   === ETSI ISDN ===
    PROT DISC  : 08h = Q.931 user-network call control message
    LEN CALL R : 2
    CALL REF   : 25
    MESS TYPE  : 5Ah = Release complete
    --- REL COMP ---
     --- CAUSE ---
     CODING STD : .00..... = CCITT standardized coding
     LOCATION   : ....0001 = private network serving the local user
     CAUSE VAL  : .0010000 = normal call clearing
LU1 mot switch SLink1 00:17.589 
  === LAPD ===
   --- ADDRESS ---
   SAPI       : 0 = call control procedures
   CR         : ......0.
   EA0        : .......0
   TEI        : 0 = non-automatic TEI assignment user equipment
   EA1        : .......1
   --- CONTROL ---
   --- S FRAME ---
   S FORMAT   : ......01
   SFB        : ....00.. = RR (receive ready)
   P/F        : .......0
   N(R)       : 32
LU1 mot switch SLink1 00:21.337 
  === LAPD ===
   --- ADDRESS ---
   SAPI       : 0 = call control procedures
   CR         : ......1.
   EA0        : .......0
   TEI        : 0 = non-automatic TEI assignment user equipment
   EA1        : .......1
   --- CONTROL ---
   --- I FRAME ---
   I FORMAT   : .......0
   N(S)       : 48
   P          : .......0
   N(R)       : 32
   === ETSI ISDN ===
    PROT DISC  : 08h = Q.931 user-network call control message
    LEN CALL R : 2
    CALL REF   : 3463
    MESS TYPE  : 05h = Setup
    --- SETUP ---
     --- BEARER CAP ---
     CODING STD : .00..... = CCITT standardized coding
     INFO TC    : ...00000 = speech
     TRANS MODE : .00..... = circuit mode
     INFO TR    : ...10000 = 64 kbit/s
     LAYER ID   : .01.....
     USRINFO L1 : ...00011 = recommendation G.711 A-law
     --- CHANNEL ID ---
     INT ID PRS : .0...... = interface implicitly identified
     INT TYPE   : ..1..... = other interface
     PREF/EXCL  : ....0... = indicated channel is preferred
     D-CHANNEL  : .....0.. = the channel identified is not the D-channel
     INFCHANNEL : ......01 = B1 channel
     CODING STD : .00..... = CCITT standardized coding
     NUMBER/MAP : ...0.... = channel is indicated by the number in the 
following octet
     CHANNL/MAP : ....0011 = B-channel units
     CHANNEL NO : 81h
     --- CALLING NO ---
     TYPE OF NO : .010.... = national number
     NUMB PLAN  : ....0001 = ISDN/telephony numbering plan (Recommendation 
E.164)
     PRES IND   : .00..... = presentation allowed
     SCREENING  : ......11 = network provided
     NO DIGITS  : '98013356'
     --- CALLED NO ---
     TYPE OF NO : .010.... = national number
     NUMB PLAN  : ....0001 = ISDN/telephony numbering plan (Recommendation 
E.164)
     NO DIGITS  : '21973552'
LU1 mot Briz SLink1   00:21.338 
  === LAPD ===
   --- ADDRESS ---
   SAPI       : 0 = call control procedures
   CR         : ......1.
   EA0        : .......0
   TEI        : 0 = non-automatic TEI assignment user equipment
   EA1        : .......1
   --- CONTROL ---
   --- S FRAME ---
   S FORMAT   : ......01
   SFB        : ....00.. = RR (receive ready)
   P/F        : .......0
   N(R)       : 49
LU1 mot Briz SLink1   00:21.340 
  === LAPD ===
   --- ADDRESS ---
   SAPI       : 0 = call control procedures
   CR         : ......0.
   EA0        : .......0
   TEI        : 0 = non-automatic TEI assignment user equipment
   EA1        : .......1
   --- CONTROL ---
   --- I FRAME ---
   I FORMAT   : .......0
   N(S)       : 32
   P          : .......0
   N(R)       : 49
   === ETSI ISDN ===
    PROT DISC  : 08h = Q.931 user-network call control message
    LEN CALL R : 2
    CALL REF   : 3463
    MESS TYPE  : 02h = Call proceeding
    --- CALL PROC ---
     --- CHANNEL ID ---
     INT ID PRS : .0...... = interface implicitly identified
     INT TYPE   : ..1..... = other interface
     PREF/EXCL  : ....1... = exclusive: only the indicated channel is acceptable
     D-CHANNEL  : .....0.. = the channel identified is not the D-channel
     INFCHANNEL : ......01 = B1 channel
     CODING STD : .00..... = CCITT standardized coding
     NUMBER/MAP : ...0.... = channel is indicated by the number in the 
following octet
     CHANNL/MAP : ....0011 = B-channel units
     CHANNEL NO : 81h
LU1 mot switch SLink1 00:21.344 
  === LAPD ===
   --- ADDRESS ---
   SAPI       : 0 = call control procedures
   CR         : ......0.
   EA0        : .......0
   TEI        : 0 = non-automatic TEI assignment user equipment
   EA1        : .......1
   --- CONTROL ---
   --- S FRAME ---
   S FORMAT   : ......01
   SFB        : ....00.. = RR (receive ready)
   P/F        : .......0
   N(R)       : 33
LU1 mot Briz SLink1   00:21.474 
 Error: PDU is longer than expected
  === LAPD ===
   --- ADDRESS ---
   SAPI       : 0 = call control procedures
   CR         : ......0.
   EA0        : .......0
   TEI        : 0 = non-automatic TEI assignment user equipment
   EA1        : .......1
   --- CONTROL ---
   --- I FRAME ---
   I FORMAT   : .......0
   N(S)       : 33
   P          : .......0
   N(R)       : 49
   === ETSI ISDN ===
    PROT DISC  : 08h = Q.931 user-network call control message
    LEN CALL R : 2
    CALL REF   : 26
    MESS TYPE  : 05h = Setup
    --- SETUP ---
     --- BEARER CAP ---
     CODING STD : .00..... = CCITT standardized coding
     INFO TC    : ...00000 = speech
     TRANS MODE : .00..... = circuit mode
     INFO TR    : ...10000 = 64 kbit/s
     LAYER ID   : .01.....
     USRINFO L1 : ...00011 = recommendation G.711 A-law
     --- CHANNEL ID ---
     INT ID PRS : .0...... = interface implicitly identified
     INT TYPE   : ..1..... = other interface
     PREF/EXCL  : ....1... = exclusive: only the indicated channel is acceptable
     D-CHANNEL  : .....0.. = the channel identified is not the D-channel
     INFCHANNEL : ......01 = B1 channel
     CODING STD : .00..... = CCITT standardized coding
     NUMBER/MAP : ...0.... = channel is indicated by the number in the 
following octet
     CHANNL/MAP : ....0011 = B-channel units
     CHANNEL NO : 82h
     --- CALLING NO ---
     TYPE OF NO : .010.... = national number
     NUMB PLAN  : ....0001 = ISDN/telephony numbering plan (Recommendation 
E.164)
     PRES IND   : .00..... = presentation allowed
     SCREENING  : ......11 = network provided
     NO DIGITS  : '21973552'
     --- CALLED NO ---
     TYPE OF NO : .010.... = national number
     NUMB PLAN  : ....0001 = ISDN/telephony numbering plan (Recommendation 
E.164)
     NO DIGITS  : '48869440'
  BYTE DUMP  : 74 0B 21 01 82 34 38 38 36 39 34 34 30h
LU1 mot switch SLink1 00:21.479 
  === LAPD ===
   --- ADDRESS ---
   SAPI       : 0 = call control procedures
   CR         : ......0.
   EA0        : .......0
   TEI        : 0 = non-automatic TEI assignment user equipment
   EA1        : .......1
   --- CONTROL ---
   --- S FRAME ---
   S FORMAT   : ......01
   SFB        : ....00.. = RR (receive ready)
   P/F        : .......0
   N(R)       : 34
LU1 mot switch SLink1 00:21.633 
  === LAPD ===
   --- ADDRESS ---
   SAPI       : 0 = call control procedures
   CR         : ......1.
   EA0        : .......0
   TEI        : 0 = non-automatic TEI assignment user equipment
   EA1        : .......1
   --- CONTROL ---
   --- I FRAME ---
   I FORMAT   : .......0
   N(S)       : 49
   P          : .......0
   N(R)       : 34
   === ETSI ISDN ===
    PROT DISC  : 08h = Q.931 user-network call control message
    LEN CALL R : 2
    CALL REF   : 26
    MESS TYPE  : 02h = Call proceeding
    --- CALL PROC ---
     --- CHANNEL ID ---
     INT ID PRS : .0...... = interface implicitly identified
     INT TYPE   : ..1..... = other interface
     PREF/EXCL  : ....1... = exclusive: only the indicated channel is acceptable
     D-CHANNEL  : .....0.. = the channel identified is not the D-channel
     INFCHANNEL : ......01 = B1 channel
     CODING STD : .00..... = CCITT standardized coding
     NUMBER/MAP : ...0.... = channel is indicated by the number in the 
following octet
     CHANNL/MAP : ....0011 = B-channel units
     CHANNEL NO : 82h
LU1 mot Briz SLink1   00:21.635 
  === LAPD ===
   --- ADDRESS ---
   SAPI       : 0 = call control procedures
   CR         : ......1.
   EA0        : .......0
   TEI        : 0 = non-automatic TEI assignment user equipment
   EA1        : .......1
   --- CONTROL ---
   --- S FRAME ---
   S FORMAT   : ......01
   SFB        : ....00.. = RR (receive ready)
   P/F        : .......0
   N(R)       : 50
LU1 mot switch SLink1 00:26.382 
  === LAPD ===
   --- ADDRESS ---
   SAPI       : 0 = call control procedures
   CR         : ......1.
   EA0        : .......0
   TEI        : 0 = non-automatic TEI assignment user equipment
   EA1        : .......1
   --- CONTROL ---
   --- I FRAME ---
   I FORMAT   : .......0
   N(S)       : 50
   P          : .......0
   N(R)       : 34
   === ETSI ISDN ===
    PROT DISC  : 08h = Q.931 user-network call control message
    LEN CALL R : 2
    CALL REF   : 26
    MESS TYPE  : 01h = Alerting
    --- ALERTING ---
     --- PROGR IND ---
     CODING STD : .00..... = CCITT standardized coding
     LOCATION   : ....0100 = public network serving the remote user
     PROGRDESCR : .0001000 = in-band information or an appropiate pattern is 
now available
LU1 mot Briz SLink1   00:26.384 
  === LAPD ===
   --- ADDRESS ---
   SAPI       : 0 = call control procedures
   CR         : ......1.
   EA0        : .......0
   TEI        : 0 = non-automatic TEI assignment user equipment
   EA1        : .......1
   --- CONTROL ---
   --- S FRAME ---
   S FORMAT   : ......01
   SFB        : ....00.. = RR (receive ready)
   P/F        : .......0
   N(R)       : 51
LU1 mot Briz SLink1   00:26.389 
  === LAPD ===
   --- ADDRESS ---
   SAPI       : 0 = call control procedures
   CR         : ......0.
   EA0        : .......0
   TEI        : 0 = non-automatic TEI assignment user equipment
   EA1        : .......1
   --- CONTROL ---
   --- I FRAME ---
   I FORMAT   : .......0
   N(S)       : 34
   P          : .......0
   N(R)       : 51
   === ETSI ISDN ===
    PROT DISC  : 08h = Q.931 user-network call control message
    LEN CALL R : 2
    CALL REF   : 3463
    MESS TYPE  : 01h = Alerting
    --- ALERTING ---
     --- PROGR IND ---
     CODING STD : .00..... = CCITT standardized coding
     LOCATION   : ....0001 = private network serving the local user
     PROGRDESCR : .0001000 = in-band information or an appropiate pattern is 
now available
LU1 mot switch SLink1 00:26.393 
  === LAPD ===
   --- ADDRESS ---
   SAPI       : 0 = call control procedures
   CR         : ......0.
   EA0        : .......0
   TEI        : 0 = non-automatic TEI assignment user equipment
   EA1        : .......1
   --- CONTROL ---
   --- S FRAME ---
   S FORMAT   : ......01
   SFB        : ....00.. = RR (receive ready)
   P/F        : .......0
   N(R)       : 35
LU1 mot Briz SLink1   00:27.080 
  === LAPD ===
   --- ADDRESS ---
   SAPI       : 0 = call control procedures
   CR         : ......0.
   EA0        : .......0
   TEI        : 0 = non-automatic TEI assignment user equipment
   EA1        : .......1
   --- CONTROL ---
   --- S FRAME ---
   S FORMAT   : ......01
   SFB        : ....00.. = RR (receive ready)
   P/F        : .......1
   N(R)       : 51
LU1 mot switch SLink1 00:27.084 
  === LAPD ===
   --- ADDRESS ---
   SAPI       : 0 = call control procedures
   CR         : ......0.
   EA0        : .......0
   TEI        : 0 = non-automatic TEI assignment user equipment
   EA1        : .......1
   --- CONTROL ---
   --- S FRAME ---
   S FORMAT   : ......01
   SFB        : ....00.. = RR (receive ready)
   P/F        : .......1
   N(R)       : 35
LU1 mot switch SLink1 00:27.833 
  === LAPD ===
   --- ADDRESS ---
   SAPI       : 0 = call control procedures
   CR         : ......1.
   EA0        : .......0
   TEI        : 0 = non-automatic TEI assignment user equipment
   EA1        : .......1
   --- CONTROL ---
   --- I FRAME ---
   I FORMAT   : .......0
   N(S)       : 51
   P          : .......0
   N(R)       : 35
   === ETSI ISDN ===
    PROT DISC  : 08h = Q.931 user-network call control message
    LEN CALL R : 2
    CALL REF   : 26
    MESS TYPE  : 07h = Connect
    --- CONNECT ---
LU1 mot Briz SLink1   00:27.835 
  === LAPD ===
   --- ADDRESS ---
   SAPI       : 0 = call control procedures
   CR         : ......0.
   EA0        : .......0
   TEI        : 0 = non-automatic TEI assignment user equipment
   EA1        : .......1
   --- CONTROL ---
   --- I FRAME ---
   I FORMAT   : .......0
   N(S)       : 35
   P          : .......0
   N(R)       : 52
   === ETSI ISDN ===
    PROT DISC  : 08h = Q.931 user-network call control message
    LEN CALL R : 2
    CALL REF   : 26
    MESS TYPE  : 0Fh = Connect acknowledge
    --- CONN ACK ---
LU1 mot switch SLink1 00:27.839 
  === LAPD ===
   --- ADDRESS ---
   SAPI       : 0 = call control procedures
   CR         : ......0.
   EA0        : .......0
   TEI        : 0 = non-automatic TEI assignment user equipment
   EA1        : .......1
   --- CONTROL ---
   --- S FRAME ---
   S FORMAT   : ......01
   SFB        : ....00.. = RR (receive ready)
   P/F        : .......0
   N(R)       : 36
LU1 mot Briz SLink1   00:27.849 
  === LAPD ===
   --- ADDRESS ---
   SAPI       : 0 = call control procedures
   CR         : ......0.
   EA0        : .......0
   TEI        : 0 = non-automatic TEI assignment user equipment
   EA1        : .......1
   --- CONTROL ---
   --- I FRAME ---
   I FORMAT   : .......0
   N(S)       : 36
   P          : .......0
   N(R)       : 52
   === ETSI ISDN ===
    PROT DISC  : 08h = Q.931 user-network call control message
    LEN CALL R : 2
    CALL REF   : 3463
    MESS TYPE  : 07h = Connect
    --- CONNECT ---
     --- CHANNEL ID ---
     INT ID PRS : .0...... = interface implicitly identified
     INT TYPE   : ..1..... = other interface
     PREF/EXCL  : ....1... = exclusive: only the indicated channel is acceptable
     D-CHANNEL  : .....0.. = the channel identified is not the D-channel
     INFCHANNEL : ......01 = B1 channel
     CODING STD : .00..... = CCITT standardized coding
     NUMBER/MAP : ...0.... = channel is indicated by the number in the 
following octet
     CHANNL/MAP : ....0011 = B-channel units
     CHANNEL NO : 81h
     --- PROGR IND ---
     CODING STD : .00..... = CCITT standardized coding
     LOCATION   : ....0001 = private network serving the local user
     PROGRDESCR : .0000010 = destination address is non ISDN
LU1 mot switch SLink1 00:27.854 
  === LAPD ===
   --- ADDRESS ---
   SAPI       : 0 = call control procedures
   CR         : ......0.
   EA0        : .......0
   TEI        : 0 = non-automatic TEI assignment user equipment
   EA1        : .......1
   --- CONTROL ---
   --- S FRAME ---
   S FORMAT   : ......01
   SFB        : ....00.. = RR (receive ready)
   P/F        : .......0
   N(R)       : 37
LU1 mot switch SLink1 00:27.933 
  === LAPD ===
   --- ADDRESS ---
   SAPI       : 0 = call control procedures
   CR         : ......1.
   EA0        : .......0
   TEI        : 0 = non-automatic TEI assignment user equipment
   EA1        : .......1
   --- CONTROL ---
   --- I FRAME ---
   I FORMAT   : .......0
   N(S)       : 52
   P          : .......0
   N(R)       : 37
   === ETSI ISDN ===
    PROT DISC  : 08h = Q.931 user-network call control message
    LEN CALL R : 2
    CALL REF   : 3463
    MESS TYPE  : 0Fh = Connect acknowledge
    --- CONN ACK ---
LU1 mot Briz SLink1   00:27.934 
  === LAPD ===
   --- ADDRESS ---
   SAPI       : 0 = call control procedures
   CR         : ......1.
   EA0        : .......0
   TEI        : 0 = non-automatic TEI assignment user equipment
   EA1        : .......1
   --- CONTROL ---
   --- S FRAME ---
   S FORMAT   : ......01
   SFB        : ....00.. = RR (receive ready)
   P/F        : .......0
   N(R)       : 53
LU1 mot switch SLink1 00:29.936 
  === LAPD ===
   --- ADDRESS ---
   SAPI       : 0 = call control procedures
   CR         : ......1.
   EA0        : .......0
   TEI        : 0 = non-automatic TEI assignment user equipment
   EA1        : .......1
   --- CONTROL ---
   --- I FRAME ---
   I FORMAT   : .......0
   N(S)       : 53
   P          : .......0
   N(R)       : 37
   === ETSI ISDN ===
    PROT DISC  : 08h = Q.931 user-network call control message
    LEN CALL R : 2
    CALL REF   : 26
    MESS TYPE  : 45h = Disconnect
    --- DISCONNECT ---
     --- CAUSE ---
     CODING STD : .00..... = CCITT standardized coding
     LOCATION   : ....0010 = public network serving the local user
     CAUSE VAL  : .0010000 = normal call clearing
LU1 mot Briz SLink1   00:29.938 
  === LAPD ===
   --- ADDRESS ---
   SAPI       : 0 = call control procedures
   CR         : ......1.
   EA0        : .......0
   TEI        : 0 = non-automatic TEI assignment user equipment
   EA1        : .......1
   --- CONTROL ---
   --- S FRAME ---
   S FORMAT   : ......01
   SFB        : ....00.. = RR (receive ready)
   P/F        : .......0
   N(R)       : 54
LU1 mot Briz SLink1   00:30.522 
  === LAPD ===
   --- ADDRESS ---
   SAPI       : 0 = call control procedures
   CR         : ......0.
   EA0        : .......0
   TEI        : 0 = non-automatic TEI assignment user equipment
   EA1        : .......1
   --- CONTROL ---
   --- I FRAME ---
   I FORMAT   : .......0
   N(S)       : 37
   P          : .......0
   N(R)       : 54
   === ETSI ISDN ===
    PROT DISC  : 08h = Q.931 user-network call control message
    LEN CALL R : 2
    CALL REF   : 26
    MESS TYPE  : 4Dh = Release
    --- RELEASE ---
     --- CAUSE ---
     CODING STD : .00..... = CCITT standardized coding
     LOCATION   : ....0001 = private network serving the local user
     CAUSE VAL  : .0010000 = normal call clearing
LU1 mot Briz SLink1   00:30.524 
  === LAPD ===
   --- ADDRESS ---
   SAPI       : 0 = call control procedures
   CR         : ......0.
   EA0        : .......0
   TEI        : 0 = non-automatic TEI assignment user equipment
   EA1        : .......1
   --- CONTROL ---
   --- I FRAME ---
   I FORMAT   : .......0
   N(S)       : 38
   P          : .......0
   N(R)       : 54
   === ETSI ISDN ===
    PROT DISC  : 08h = Q.931 user-network call control message
    LEN CALL R : 2
    CALL REF   : 3463
    MESS TYPE  : 45h = Disconnect
    --- DISCONNECT ---
     --- CAUSE ---
     CODING STD : .00..... = CCITT standardized coding
     LOCATION   : ....0001 = private network serving the local user
     CAUSE VAL  : .0010000 = normal call clearing
LU1 mot switch SLink1 00:30.527 
  === LAPD ===
   --- ADDRESS ---
   SAPI       : 0 = call control procedures
   CR         : ......0.
   EA0        : .......0
   TEI        : 0 = non-automatic TEI assignment user equipment
   EA1        : .......1
   --- CONTROL ---
   --- S FRAME ---
   S FORMAT   : ......01
   SFB        : ....00.. = RR (receive ready)
   P/F        : .......0
   N(R)       : 38
LU1 mot switch SLink1 00:30.533 
  === LAPD ===
   --- ADDRESS ---
   SAPI       : 0 = call control procedures
   CR         : ......0.
   EA0        : .......0
   TEI        : 0 = non-automatic TEI assignment user equipment
   EA1        : .......1
   --- CONTROL ---
   --- S FRAME ---
   S FORMAT   : ......01
   SFB        : ....00.. = RR (receive ready)
   P/F        : .......0
   N(R)       : 39
LU1 mot switch SLink1 00:30.582 
  === LAPD ===
   --- ADDRESS ---
   SAPI       : 0 = call control procedures
   CR         : ......1.
   EA0        : .......0
   TEI        : 0 = non-automatic TEI assignment user equipment
   EA1        : .......1
   --- CONTROL ---
   --- I FRAME ---
   I FORMAT   : .......0
   N(S)       : 54
   P          : .......0
   N(R)       : 39
   === ETSI ISDN ===
    PROT DISC  : 08h = Q.931 user-network call control message
    LEN CALL R : 2
    CALL REF   : 26
    MESS TYPE  : 5Ah = Release complete
    --- REL COMP ---
LU1 mot Briz SLink1   00:30.583 
  === LAPD ===
   --- ADDRESS ---
   SAPI       : 0 = call control procedures
   CR         : ......1.
   EA0        : .......0
   TEI        : 0 = non-automatic TEI assignment user equipment
   EA1        : .......1
   --- CONTROL ---
   --- S FRAME ---
   S FORMAT   : ......01
   SFB        : ....00.. = RR (receive ready)
   P/F        : .......0
   N(R)       : 55
LU1 mot switch SLink1 00:30.733 
  === LAPD ===
   --- ADDRESS ---
   SAPI       : 0 = call control procedures
   CR         : ......1.
   EA0        : .......0
   TEI        : 0 = non-automatic TEI assignment user equipment
   EA1        : .......1
   --- CONTROL ---
   --- I FRAME ---
   I FORMAT   : .......0
   N(S)       : 55
   P          : .......0
   N(R)       : 39
   === ETSI ISDN ===
    PROT DISC  : 08h = Q.931 user-network call control message
    LEN CALL R : 2
    CALL REF   : 3463
    MESS TYPE  : 4Dh = Release
    --- RELEASE ---
LU1 mot Briz SLink1   00:30.734 
  === LAPD ===
   --- ADDRESS ---
   SAPI       : 0 = call control procedures
   CR         : ......1.
   EA0        : .......0
   TEI        : 0 = non-automatic TEI assignment user equipment
   EA1        : .......1
   --- CONTROL ---
   --- S FRAME ---
   S FORMAT   : ......01
   SFB        : ....00.. = RR (receive ready)
   P/F        : .......0
   N(R)       : 56
LU1 mot Briz SLink1   00:30.736 
  === LAPD ===
   --- ADDRESS ---
   SAPI       : 0 = call control procedures
   CR         : ......0.
   EA0        : .......0
   TEI        : 0 = non-automatic TEI assignment user equipment
   EA1        : .......1
   --- CONTROL ---
   --- I FRAME ---
   I FORMAT   : .......0
   N(S)       : 39
   P          : .......0
   N(R)       : 56
   === ETSI ISDN ===
    PROT DISC  : 08h = Q.931 user-network call control message
    LEN CALL R : 2
    CALL REF   : 3463
    MESS TYPE  : 5Ah = Release complete
    --- REL COMP ---
     --- CAUSE ---
     CODING STD : .00..... = CCITT standardized coding
     LOCATION   : ....0001 = private network serving the local user
     CAUSE VAL  : .0010000 = normal call clearing
LU1 mot switch SLink1 00:30.740 
  === LAPD ===
   --- ADDRESS ---
   SAPI       : 0 = call control procedures
   CR         : ......0.
   EA0        : .......0
   TEI        : 0 = non-automatic TEI assignment user equipment
   EA1        : .......1
   --- CONTROL ---
   --- S FRAME ---
   S FORMAT   : ......01
   SFB        : ....00.. = RR (receive ready)
   P/F        : .......0
   N(R)       : 40
LU1 mot Briz SLink1   00:37.082 
  === LAPD ===
   --- ADDRESS ---
   SAPI       : 0 = call control procedures
   CR         : ......0.
   EA0        : .......0
   TEI        : 0 = non-automatic TEI assignment user equipment
   EA1        : .......1
   --- CONTROL ---
   --- S FRAME ---
   S FORMAT   : ......01
   SFB        : ....00.. = RR (receive ready)
   P/F        : .......1
   N(R)       : 56
LU1 mot switch SLink1 00:37.086 
  === LAPD ===
   --- ADDRESS ---
   SAPI       : 0 = call control procedures
   CR         : ......0.
   EA0        : .......0
   TEI        : 0 = non-automatic TEI assignment user equipment
   EA1        : .......1
   --- CONTROL ---
   --- S FRAME ---
   S FORMAT   : ......01
   SFB        : ....00.. = RR (receive ready)
   P/F        : .......1
   N(R)       : 40
LU1 mot Briz SLink1   00:47.093 
  === LAPD ===
   --- ADDRESS ---
   SAPI       : 0 = call control procedures
   CR         : ......0.
   EA0        : .......0
   TEI        : 0 = non-automatic TEI assignment user equipment
   EA1        : .......1
   --- CONTROL ---
   --- S FRAME ---
   S FORMAT   : ......01
   SFB        : ....00.. = RR (receive ready)
   P/F        : .......1
   N(R)       : 56
LU1 mot switch SLink1 00:47.098 
  === LAPD ===
   --- ADDRESS ---
   SAPI       : 0 = call control procedures
   CR         : ......0.
   EA0        : .......0
   TEI        : 0 = non-automatic TEI assignment user equipment
   EA1        : .......1
   --- CONTROL ---
   --- S FRAME ---
   S FORMAT   : ......01
   SFB        : ....00.. = RR (receive ready)
   P/F        : .......1
   N(R)       : 40
LU1 mot Briz SLink1   00:57.105 
  === LAPD ===
   --- ADDRESS ---
   SAPI       : 0 = call control procedures
   CR         : ......0.
   EA0        : .......0
   TEI        : 0 = non-automatic TEI assignment user equipment
   EA1        : .......1
   --- CONTROL ---
   --- S FRAME ---
   S FORMAT   : ......01
   SFB        : ....00.. = RR (receive ready)
   P/F        : .......1
   N(R)       : 56
LU1 mot switch SLink1 00:57.109 
  === LAPD ===
   --- ADDRESS ---
   SAPI       : 0 = call control procedures
   CR         : ......0.
   EA0        : .......0
   TEI        : 0 = non-automatic TEI assignment user equipment
   EA1        : .......1
   --- CONTROL ---
   --- S FRAME ---
   S FORMAT   : ......01
   SFB        : ....00.. = RR (receive ready)
   P/F        : .......1
   N(R)       : 40

_______________________________________________
--Bandwidth and Colocation provided by Easynews.com --

asterisk-dev mailing list
To UNSUBSCRIBE or update options visit:
   http://lists.digium.com/mailman/listinfo/asterisk-dev