Hi there, I have been making progress over the last few months connecting an Asterisk 1.4 server to a Siemens HiPath 4000 switch via ISDN PRI.
I'm using a TE120P card configured for qsig. I managed to get Siemens to alter the configuration of the switch with the result that caller ID numbers and names are being transferred successfully from Asterisk to the HiPath; however I am encountering a problem successfully terminating calls. The problems only occur if the extension number called from Asterisk happens to be forwarded on the HiPath. If I dial an extension that is not forwarded on the HiPath, the call completes successfully, but all forwarded extensions fail to ring and I always see the same symptoms. With intense PRI debugging enabled I see output similar to that below when this happens: Length (123) of 0x30 component is too long (the length varies depending on the caller ID name associated with the forwarded extension). There are a bunch of other 'Unable to handle ROSE operation ???' errors, but I see those whether or not I dial a forwarded extension. I saw a patch specifically mentioning indefinite ASN1 lengths (http://svn.digium.com/view/libpri/branches/1.4/pri_facility.c?view=log - number 209); however I've been unable to apply the patch to version 1.4.3 of libpri. Apologies if I'm sounding really stupid here, but I'd appreciate any help applying the patch. Thanks, Chris -- Chris Notley [EMAIL PROTECTED] _______________________________________________ --Bandwidth and Colocation Provided by http://www.api-digital.com-- asterisk-dev mailing list To UNSUBSCRIBE or update options visit: http://lists.digium.com/mailman/listinfo/asterisk-dev