yeah, 100% sure abt opc/dpc, actually i(+ server) was sitting just beside
the Siemens EWSD & their tech ppl, so setting up opc/dpc was no issue.
Moreover, their side shows the link as active & aligned too, by accepting
its dpc(i.e. our opc). and when initially the opc/dpc were incorrect then
the following message occured on CLI:

Nov 25 05:56:17 WARNING[18286]: mtp.c:393 t2_timeout: MTP2 timer T2 timeout
(failed to receive 'O', 'N', or 'E' after sending 'O'), initial alignment
failed on link 'l1'.


On 12/19/06, Tomasz Paszkowski <[EMAIL PROTECTED]> wrote:


Are you sure you have set valid point codes ? You can check this using
ss7 dump command.

_______________________________________________
--Bandwidth and Colocation provided by Easynews.com --

asterisk-ss7 mailing list
To UNSUBSCRIBE or update options visit:
   http://lists.digium.com/mailman/listinfo/asterisk-ss7

Reply via email to