Jorge Valencia wrote: > Hi guys, recently i noticed that some calls between switch (ZTE ZXG10) > and my libss7 machines in the ACM message in the parameters have a > randomly charge indicator to values 0 or 2. Dont know if there's a > problem, but other telcos that we interconnect says the parameter no > charge was set and then so the calls was not charged. > > Can i set up a always charge parameter in ACM?
Right now, it is hard coded and set to default to "No Indication" in the backwards call indicator parameter. I talked with Jorge on MSN, and he's going to try to hard code it to "Charge" instead, to see if it fixes his issue. If it does, we might add a configuration parameter for this. Matthew Fredrickson Digium, Inc. _______________________________________________ --Bandwidth and Colocation Provided by http://www.api-digital.com-- asterisk-ss7 mailing list To UNSUBSCRIBE or update options visit: http://lists.digium.com/mailman/listinfo/asterisk-ss7