Simone Vasoli (BK s.r.l.) wrote:
Hi,
when I make a call, chan_capi always uses controller 2, and never uses
controller 1 (so I have 4 lines for incoming calls, but only 2 lines
instead of 4 for outgoing calls).

this is with 2 AVM Fritz cards PCI.

You can only use one Fritz PCI card per box due to a limitation built into the AVM CAPI driver.


However you can get around this by hacking the (binary) fcpci kernel module and changing the name of second and subsequent modules. I haven't tried it personally, but I think there are several people who are using this technique sucessfully :).

Just in case anyone is interested, AVM also say that you can't use the Fritz card and the B1 card in the same box. However I have found it seems to work fine provided the B1 CAPI driver is loaded *after* the Fritz driver.

--
Jamie Neil | <[EMAIL PROTECTED]> | 0870 7777 454
Versado I.T. Services Ltd. | http://versado.net/ | 0845 450 1254

_______________________________________________
Asterisk-Users mailing list
[EMAIL PROTECTED]
http://lists.digium.com/mailman/listinfo/asterisk-users