Hi, Ok, I put the new TE410 into our system last night - This is the second TE410P card. There is also TDM400P in Slot 5 with IRQ 9 which is shared with aic7xxx (SCSI)
According to "cat /proc/interrupts", the new card is in the second slot using IRQ 11 (the first card is in slot 1 on IRQ 10 - but always has been). With only the original card install, there has been no issues with alarms. Currently, I have card 2 Looped back to each other - no active connections - Port 1 => 3 & Port 2 => 4) I came in this morning and channel 25 has been going into Yellow Alarm on and off since midnight according to the logs. (12 times from 4:13 am to 8:04 Pacific) Card 1 has Telco provided T1's on Port 3 & 4 and in-house phone system on Port 1 and 2. Asterisk is program to route call from Port 3 or 4 to the appropriate in-house system according to the DNIS digits received. All T1's are setup as D4, AMI, SF and E&M Wink. The timing source is Port 4 on Card 1 - but not sure if this is needed. Any clues what I should look at now? Thanks Bart _______________________________________________ Asterisk-Users mailing list [email protected] http://lists.digium.com/mailman/listinfo/asterisk-users To UNSUBSCRIBE or update options visit: http://lists.digium.com/mailman/listinfo/asterisk-users