I have a TE410P with four T1's going into it. Things look roughly like this:
#1 Goes to PBX -- we're responsible for timing #2 E&M span to telco 1 #3 PRI span to telco 1 #4 PRI span to telco 2
If I set primary sync source to span 2, users report strange echo, distortion, and crosstalk problems, which sound remarkably like frame slippage on spans 3 and 4. If I set it to use #3 as primary, the other spans report problems, etc. Generally, it seems like the clocks just aren't quite close enough to make things work right all of the time. I don't forsee either involved telco doing anything at all about this.
Is there any way to see if there is some sort of weird timing problem? Even better, is there a way to get things to work right on the TE410P?
Thanks :-) -rt
-- Ryan Tucker Network Engineer NetAccess, Inc. 1159 Pittsford-Victor Road Bldg. 5, Suite 140 Pittsford, New York 14534 585-419-8200 www.netacc.net _______________________________________________ Asterisk-Users mailing list [EMAIL PROTECTED] http://lists.digium.com/mailman/listinfo/asterisk-users