Paul Herman wrote:
Hi there,
This'll be an easy answer for a lot of you, just wanna make sure:
We ordered a 2 phone line package from SBC in Chicago (two numbers,
one main number), pretty basic & straigt forward. The line to the
building is a four wire line with an RJ-11 connector. We want to
connect both of these lines to a TDM400P with FXO modules.
Q: First of all, is there one line per pair of wires, and m I right
in thinking that I have to break out / splice the two middle wires
from the two outside ones, and connect each pair to a separate port on
the TDM400P card? (i.e pins 2,5 to pin 3,4 on one port and pins 3,4
to pins 3,4 on the other port?)
i.e. the TDM400P can't span two channels on one port, correct?
Thanks,
-Paul.
___
Correct on all counts.
Good luck with Ameritech ( SBC )
You'll need it!
John Novack
_______________________________________________
--Bandwidth and Colocation sponsored by Easynews.com --
Asterisk-Users mailing list
[email protected]
http://lists.digium.com/mailman/listinfo/asterisk-users
To UNSUBSCRIBE or update options visit:
http://lists.digium.com/mailman/listinfo/asterisk-users