On Mon, Apr 24, 2006 at 07:21:18AM +0800, Leo Ann Boon wrote: > Louis-David Mitterrand wrote:<snip> > > >Should I use a T1 cross cable to connect the telco's socket to the > >TE410P card? > > > >When I tried straight cat5 cables, both leds remained red at each end. > >However this E1 socket works fine with the Matra PBX, so it must be a > >cable problem or TE410P misconfiguration. > > > Louis, > > Sanity check: Is your straight cat5 cable really straight? As in 1-1, > 2-2, ... 8-8. The regular 'straight' ethernet cable is not straight, > pins 4 and 6 are crossed.
Hi Leo, I was using regular ethernet "straight" cable. So this might explain the problem. I really was not aware of pins 4 and 6 being crossed on eth cable. Thanks for the heads up. _______________________________________________ --Bandwidth and Colocation provided by Easynews.com -- Asterisk-Users mailing list To UNSUBSCRIBE or update options visit: http://lists.digium.com/mailman/listinfo/asterisk-users