Hey guys

This is probably for Armin, but I thought maybe someone else might have something I could try. I'm having a problem with one of my Eicon Diva V-4BRI cards and I'm trying to work out if its a driver configuration error, card failure or telco problem:

I have an Asterisk box running -- the Eicon drivers see all four ports on my card, capi.conf is configured with all four ports and when I issue a "capi info" on the Asterisk CLI, I see all four ports.

The problem is, I only have two ISDN2 lines connected, to ports one and two. I configured capi.conf with only two controllers, but Asterisk still sees all four. If I try to dial-out on anything but the first port, it just hangs (and I get an engaged tone once two lines are up, suggesting that the 2nd port just isn't working properly).

However, I've swapped cables and NT1s, and both lines work in Port 1 of the Eicon Diva. But I can't see any configuration difference between this server and the other server I have that is working fine across its two ports.

Does anyone know of any Eicon diagnostics I can run to see if the second port is actually up? I've been through the Diva webinterface, but I'm not actually sure what to look for!

Thanks,
Avi

--
National Manager - Special Projects

< Sydney / Melbourne / Canberra / Hobart / London />
  2/340 Gore Street      T: +61 (0) 3 9486 0411
  Fitzroy, VIC           F: +61 (0) 3 9486 0611
  3065                   W: http://www.squiz.net/

.....>> Open Source  - Own it  -  Squiz.net ...../>
_______________________________________________
--Bandwidth and Colocation provided by Easynews.com --

Asterisk-Users mailing list
To UNSUBSCRIBE or update options visit:
  http://lists.digium.com/mailman/listinfo/asterisk-users