I have many problems with this server and two cards TE4110P, because after
several minutes
one of two cards stays out without sending anyone alarm and then offer a NMI
alarm i suppose
that it is to cause the sharing IRQ, it´s a ticket for a DIGIUM

-----Mensaje original-----
De: [EMAIL PROTECTED]
[mailto:[EMAIL PROTECTED] nombre de stoffell
Enviado el: Sábado, 20 de Mayo de 2006 07:29 a.m.
Para: Asterisk Users Mailing List - Non-Commercial Discussion
Asunto: Re: [Asterisk-Users] DELL PowerEdge 2850 and TE4110P and TE110P


On 5/18/06, Remco Barende <[EMAIL PROTECTED]> wrote:
> Also the 2850 is *always* sharing IRQ's on every PCI slot, you need to buy
> a dual port ethernet adapter which will use only one irq to free up an IRQ
> on another slot. This just totally sucks and irq sharing in a box with
> only 3 pci slots is totally unnecessary

Because we only needed 1 NIC, we disabled the 2nd onboard NIC. That
made 1 pci slot free of IRQ sharing, making the system stable and
performing very well.

cheers
_______________________________________________
--Bandwidth and Colocation provided by Easynews.com --

Asterisk-Users mailing list
To UNSUBSCRIBE or update options visit:
   http://lists.digium.com/mailman/listinfo/asterisk-users


_______________________________________________
--Bandwidth and Colocation provided by Easynews.com --

Asterisk-Users mailing list
To UNSUBSCRIBE or update options visit:
   http://lists.digium.com/mailman/listinfo/asterisk-users

Reply via email to