Maybe you want to provide a full log (including call of the first channel
and the hangup) to my personal mail?

I just added an attachment to this mail.

Thanks a lot :-)

P.S.: this log was generated with verbosity to 5 and with capi debug

_________________________________________________________________
Découvrez le Blog heroic Fantaisy d'Eragon! http://eragon-heroic-fantasy.spaces.live.com/

*CLI> CONNECT_IND ID=002 #0x168a LEN=0041
 Controller/PLCI/NCCI            = 0x401
 CIPValue                        = 0x10
 CalledPartyNumber               = <81>123
 CallingPartyNumber              = <00 83>107
 CalledPartySubaddress           = default
 CallingPartySubaddress          = default
 BC                              = <80 90 a3>
 LLC                             = default
 HLC                             = <91 81>
 AdditionalInfo
  BChannelinformation            = default
  Keypadfacility                 = default
  Useruserdata                   = default
  Facilitydataarray              = default
  SendingComplete                = default

   -- CONNECT_IND (PLCI=0x401,DID=123,CID=107,CIP=0x10,CONTROLLER=0x1)
      > contr1#02: msn='*' DNID='123' DID
 == contr1#02: setting format alaw - 0x8 (alaw)
 == contr1#02: Incoming call '107' -> '123'
INFO_IND ID=002 #0x168b LEN=0019
 Controller/PLCI/NCCI            = 0x401
 InfoNumber                      = 0x70
 InfoElement                     = <81>123
*CLI> INFO_IND ID=002 #0x3530 LEN=0036
 Controller/PLCI/NCCI            = 0x301
 InfoNumber                      = 0x1c
InfoElement = <91 a1 12 02 01>t<02 01 22>0<0a a1 05>0<03 02 01 00 82 01 01>

INFO_RESP ID=002 #0x3530 LEN=0012
 Controller/PLCI/NCCI            = 0x301

   -- contr1#01: info element FACILITY
INFO_IND ID=002 #0x3531 LEN=0017
 Controller/PLCI/NCCI            = 0x301
 InfoNumber                      = 0x1e
 InfoElement                     = <81 88>

INFO_RESP ID=002 #0x3531 LEN=0012
 Controller/PLCI/NCCI            = 0x301

   -- contr1#01: info element PI 81 88
      > contr1#01: In-band information available
INFO_IND ID=002 #0x3532 LEN=0017
 Controller/PLCI/NCCI            = 0x301
 InfoNumber                      = 0x8
 InfoElement                     = <80 90>

INFO_RESP ID=002 #0x3532 LEN=0012
 Controller/PLCI/NCCI            = 0x301

   -- contr1#01: info element CAUSE 80 90
INFO_IND ID=002 #0x3533 LEN=0015
 Controller/PLCI/NCCI            = 0x301
 InfoNumber                      = 0x8045
 InfoElement                     = default

INFO_RESP ID=002 #0x3533 LEN=0012
 Controller/PLCI/NCCI            = 0x301

   -- contr1#01: info element DISCONNECT
   -- contr1#01: Disconnect case 1
-- CAPI queue frame:[ TYPE: Control (4) SUBCLASS: Hangup (1) ] [contr1#01]
 == contr1#01: CAPI Hangingup for PLCI=0x301 in state 2
   -- contr1#01: activehangingup (cause=16) for PLCI=0x301
DISCONNECT_B3_REQ ID=002 #0x31d3 LEN=0013
 Controller/PLCI/NCCI            = 0x260301
 NCPI                            = default

== Spawn extension (standardtelephonique, 103, 2) exited non-zero on 'CAPI/contr1#02/123-10'
 == contr1#02: CAPI Hangingup for PLCI=0x401 in state 2
   -- contr1#02: activehangingup (cause=16) for PLCI=0x401
DISCONNECT_B3_REQ ID=002 #0x31d4 LEN=0013
 Controller/PLCI/NCCI            = 0x250401
 NCPI                            = default

      > CAPI devicestate requested for contr1#01/103
      > CAPI devicestate requested for contr1#01/103
      > CAPI devicestate requested for contr1#02/123
      > CAPI devicestate requested for contr1#02/123
DISCONNECT_B3_CONF ID=002 #0x31d3 LEN=0014
 Controller/PLCI/NCCI            = 0x260301
 Info                            = 0x0

DISCONNECT_B3_CONF ID=002 #0x31d4 LEN=0014
 Controller/PLCI/NCCI            = 0x250401
 Info                            = 0x0

DISCONNECT_B3_IND ID=002 #0x3535 LEN=0015
 Controller/PLCI/NCCI            = 0x260301
 Reason_B3                       = 0x0
 NCPI                            = default

DISCONNECT_B3_RESP ID=002 #0x3535 LEN=0012
 Controller/PLCI/NCCI            = 0x260301

DISCONNECT_REQ ID=002 #0x31d5 LEN=0013
 Controller/PLCI/NCCI            = 0x301
 AdditionalInfo                  = default

DISCONNECT_B3_IND ID=002 #0x3536 LEN=0015
 Controller/PLCI/NCCI            = 0x250401
 Reason_B3                       = 0x0
 NCPI                            = default

DISCONNECT_B3_RESP ID=002 #0x3536 LEN=0012
 Controller/PLCI/NCCI            = 0x250401

DISCONNECT_REQ ID=002 #0x31d6 LEN=0013
 Controller/PLCI/NCCI            = 0x401
 AdditionalInfo                  = default

DISCONNECT_CONF ID=002 #0x31d5 LEN=0014
 Controller/PLCI/NCCI            = 0x301
 Info                            = 0x0

INFO_IND ID=002 #0x3537 LEN=0015
 Controller/PLCI/NCCI            = 0x301
 InfoNumber                      = 0x805a
 InfoElement                     = default

INFO_RESP ID=002 #0x3537 LEN=0012
 Controller/PLCI/NCCI            = 0x301

   -- contr1#01: info element RELEASE COMPLETE
DISCONNECT_IND ID=002 #0x3539 LEN=0014
 Controller/PLCI/NCCI            = 0x301
 Reason                          = 0x3490

DISCONNECT_RESP ID=002 #0x3539 LEN=0012
 Controller/PLCI/NCCI            = 0x301

      > contr1#01: CAPI INFO 0x3490: Normal call clearing
 == contr1#01: Interface cleanup PLCI=0x301
DISCONNECT_CONF ID=002 #0x31d6 LEN=0014
 Controller/PLCI/NCCI            = 0x401
 Info                            = 0x0

INFO_IND ID=002 #0x353a LEN=0036
 Controller/PLCI/NCCI            = 0x401
 InfoNumber                      = 0x1c
InfoElement = <91 a1 12 02 01>u<02 01 22>0<0a a1 05>0<03 02 01 00 82 01 01>

INFO_RESP ID=002 #0x353a LEN=0012
 Controller/PLCI/NCCI            = 0x401

   -- contr1#02: info element FACILITY
INFO_IND ID=002 #0x353b LEN=0017
 Controller/PLCI/NCCI            = 0x401
 InfoNumber                      = 0x8
 InfoElement                     = <80 90>

INFO_RESP ID=002 #0x353b LEN=0012
 Controller/PLCI/NCCI            = 0x401

   -- contr1#02: info element CAUSE 80 90
INFO_IND ID=002 #0x353c LEN=0015
 Controller/PLCI/NCCI            = 0x401
 InfoNumber                      = 0x804d
 InfoElement                     = default

INFO_RESP ID=002 #0x353c LEN=0012
 Controller/PLCI/NCCI            = 0x401

   -- contr1#02: info element RELEASE
DISCONNECT_IND ID=002 #0x353e LEN=0014
 Controller/PLCI/NCCI            = 0x401
 Reason                          = 0x3490

DISCONNECT_RESP ID=002 #0x353e LEN=0012
 Controller/PLCI/NCCI            = 0x401

      > contr1#02: CAPI INFO 0x3490: Normal call clearing
 == contr1#02: Interface cleanup PLCI=0x401

INFO_RESP ID=002 #0x168b LEN=0012
 Controller/PLCI/NCCI            = 0x401

   -- contr1#02: info element CALLED PARTY NUMBER
   -- contr1#02: Updated channel name: CAPI/contr1#02/123-10
   -- contr1#02: CAPI/contr1#02/123-10: 123 matches in context toto
      > CAPI devicestate requested for contr1#02/123
 == Started pbx on channel CAPI/contr1#02/123-10
INFO_IND ID=002 #0x168c LEN=0015
 Controller/PLCI/NCCI            = 0x401
 InfoNumber                      = 0xa1
 InfoElement                     = default

INFO_RESP ID=002 #0x168c LEN=0012
 Controller/PLCI/NCCI            = 0x401

   -- contr1#02: info element Sending Complete
INFO_IND ID=002 #0x168d LEN=0016
 Controller/PLCI/NCCI            = 0x401
 InfoNumber                      = 0x18
 InfoElement                     = <8a>

INFO_RESP ID=002 #0x168d LEN=0012
 Controller/PLCI/NCCI            = 0x401

   -- contr1#02: info element CHANNEL IDENTIFICATION 8a
INFO_IND ID=002 #0x168e LEN=0015
 Controller/PLCI/NCCI            = 0x401
 InfoNumber                      = 0x8005
 InfoElement                     = default

INFO_RESP ID=002 #0x168e LEN=0012
 Controller/PLCI/NCCI            = 0x401

   -- contr1#02: info element SETUP
      > contr1#02: IE SETUP / SENDING-COMPLETE already received.
-- Executing [EMAIL PROTECTED]:1] NoOp("CAPI/contr1#02/123-10", "<> a compose le <123> depuis le poste <107> de type <CAP>") in new stack -- Executing [EMAIL PROTECTED]:2] Read("CAPI/contr1#02/123-10", "numero|demandeNumero") in new stack
 == contr1#02: Answering for 123
CONNECT_RESP ID=002 #0x168a LEN=0039
 Controller/PLCI/NCCI            = 0x401
 Reject                          = 0x0
 BProtocol
  B1protocol                     = 0x1
  B2protocol                     = 0x1
  B3protocol                     = 0x0
  B1configuration                = default
  B2configuration                = default
  B3configuration                = default
  GlobalConfiguration            = default
 ConnectedNumber                 = <00 80>123
 ConnectedSubaddress             = default
 LLC                             = default
 AdditionalInfo
  BChannelinformation            = default
  Keypadfacility                 = default
  Useruserdata                   = default
  Facilitydataarray              = default
  SendingComplete                = default

      > CAPI devicestate requested for contr1#02/123
   -- <CAPI/contr1#02/123-10> Playing 'demandeNumero' (language 'de')
CONNECT_ACTIVE_IND ID=002 #0x1690 LEN=0015
 Controller/PLCI/NCCI            = 0x401
 ConnectedNumber                 = default
 ConnectedSubaddress             = default
 LLC                             = default

CONNECT_ACTIVE_RESP ID=002 #0x1690 LEN=0012
 Controller/PLCI/NCCI            = 0x401

CONNECT_B3_IND ID=002 #0x1691 LEN=0013
 Controller/PLCI/NCCI            = 0x250401
 NCPI                            = default

CONNECT_B3_RESP ID=002 #0x1691 LEN=0015
 Controller/PLCI/NCCI            = 0x250401
 Reject                          = 0x0
 NCPI                            = default

CONNECT_B3_ACTIVE_IND ID=002 #0x1692 LEN=0013
 Controller/PLCI/NCCI            = 0x250401
 NCPI                            = default

CONNECT_B3_ACTIVE_RESP ID=002 #0x1692 LEN=0012
 Controller/PLCI/NCCI            = 0x250401

   -- User entered '103'
-- Executing [EMAIL PROTECTED]:3] NoOp("CAPI/contr1#02/123-10", "Voici le numero : 103") in new stack -- Executing [EMAIL PROTECTED]:4] Goto("CAPI/contr1#02/123-10", "standardtelephonique|103|1") in new stack
   -- Goto (standardtelephonique,103,1)
-- Executing [EMAIL PROTECTED]:1] NoOp("CAPI/contr1#02/123-10", "<> a compose le <123> depuis le poste <107> de type < - 0>") in new stack -- Executing [EMAIL PROTECTED]:2] Dial("CAPI/contr1#02/123-10", "CAPI/contr1/b:103||tT") in new stack
      > data = contr1/b:103 format=8
      > parsed dialstring: 'contr1' 'b' '103' ''
      > capi request controller = 1
 == contr1#01: setting format alaw - 0x8 (alaw)
      > parsed dialstring: 'contr1' 'b' '103' ''
      > capi: peerlink -1 allocated, peer is unlinked
 == contr1#01: Call CAPI/contr1#01/103-11   (pres=0x03, ton=0x00)
CONNECT_REQ ID=002 #0x13e4 LEN=0047
 Controller/PLCI/NCCI            = 0x1
 CIPValue                        = 0x1
 CalledPartyNumber               = <80>103
 CallingPartyNumber              = <00 83>b
 CalledPartySubaddress           = default
 CallingPartySubaddress          = default
 BProtocol
  B1protocol                     = 0x1
  B2protocol                     = 0x1
  B3protocol                     = 0x0
  B1configuration                = default
  B2configuration                = default
  B3configuration                = default
  GlobalConfiguration            = default
 BC                              = default
 LLC                             = default
 HLC                             = default
 AdditionalInfo
  BChannelinformation            = <00 00>
  Keypadfacility                 = default
  Useruserdata                   = default
  Facilitydataarray              = default
  SendingComplete                = default

   -- Called contr1/b:103
      > CAPI devicestate requested for contr1#01/103
CONNECT_CONF ID=002 #0x13e4 LEN=0014
 Controller/PLCI/NCCI            = 0x301
 Info                            = 0x0

   -- contr1#01: received CONNECT_CONF PLCI = 0x301
INFO_IND ID=002 #0x1727 LEN=0017
 Controller/PLCI/NCCI            = 0x301
 InfoNumber                      = 0x1e
 InfoElement                     = <81 88>

INFO_RESP ID=002 #0x1727 LEN=0012
 Controller/PLCI/NCCI            = 0x301

   -- contr1#01: info element PI 81 88
      > contr1#01: In-band information available
-- CAPI queue frame:[ TYPE: Control (4) SUBCLASS: Unknown control '14' (14) ] [contr1#01]
INFO_IND ID=002 #0x1728 LEN=0016
 Controller/PLCI/NCCI            = 0x301
 InfoNumber                      = 0x18
 InfoElement                     = <89>

INFO_RESP ID=002 #0x1728 LEN=0012
 Controller/PLCI/NCCI            = 0x301

   -- contr1#01: info element CHANNEL IDENTIFICATION 89
INFO_IND ID=002 #0x1729 LEN=0015
 Controller/PLCI/NCCI            = 0x301
 InfoNumber                      = 0x800d
 InfoElement                     = default

INFO_RESP ID=002 #0x1729 LEN=0012
 Controller/PLCI/NCCI            = 0x301

   -- contr1#01: info element SETUP ACK
-- CAPI/contr1#01/103-11 is making progress passing it to CAPI/contr1#02/123-10
 == contr1#02: Requested PROGRESS-Indication for CAPI/contr1#02/123-10
INFO_IND ID=002 #0x172b LEN=0015
 Controller/PLCI/NCCI            = 0x301
 InfoNumber                      = 0x8002
 InfoElement                     = default

INFO_RESP ID=002 #0x172b LEN=0012
 Controller/PLCI/NCCI            = 0x301

   -- contr1#01: info element CALL PROCEEDING
-- CAPI queue frame:[ TYPE: Control (4) SUBCLASS: Unknown control '15' (15) ] [contr1#01] -- CAPI/contr1#01/103-11 is proceeding passing it to CAPI/contr1#02/123-10
 == contr1#02: Requested PROCEEDING-Indication for CAPI/contr1#02/123-10
INFO_IND ID=002 #0x173a LEN=0015
 Controller/PLCI/NCCI            = 0x301
 InfoNumber                      = 0x8001
 InfoElement                     = default

INFO_RESP ID=002 #0x173a LEN=0012
 Controller/PLCI/NCCI            = 0x301

   -- contr1#01: info element ALERTING
-- CAPI queue frame:[ TYPE: Control (4) SUBCLASS: Ringing (3) ] [contr1#01]
   -- CAPI/contr1#01/103-11 is ringing
 == contr1#02: Requested RINGING-Indication for CAPI/contr1#02/123-10
   -- contr1#02: attempting ALERT in state 2
      > CAPI devicestate requested for contr1#01/103
INFO_IND ID=002 #0x1853 LEN=0020
 Controller/PLCI/NCCI            = 0x301
 InfoNumber                      = 0x29
 InfoElement                     = <07 09 06 12 03>

INFO_RESP ID=002 #0x1853 LEN=0012
 Controller/PLCI/NCCI            = 0x301

   -- contr1#01: info element Date/Time 07/09/06 18:03
INFO_IND ID=002 #0x1854 LEN=0015
 Controller/PLCI/NCCI            = 0x301
 InfoNumber                      = 0x8007
 InfoElement                     = default

INFO_RESP ID=002 #0x1854 LEN=0012
 Controller/PLCI/NCCI            = 0x301

   -- contr1#01: info element CONNECT
CONNECT_ACTIVE_IND ID=002 #0x1856 LEN=0020
 Controller/PLCI/NCCI            = 0x301
 ConnectedNumber                 = <00 83>103
 ConnectedSubaddress             = default
 LLC                             = default

CONNECT_ACTIVE_RESP ID=002 #0x1856 LEN=0012
 Controller/PLCI/NCCI            = 0x301

CONNECT_B3_REQ ID=002 #0x14fc LEN=0013
 Controller/PLCI/NCCI            = 0x301
 NCPI                            = default

   -- contr1#01: sent CONNECT_B3_REQ PLCI=0x301
CONNECT_B3_CONF ID=002 #0x14fc LEN=0014
 Controller/PLCI/NCCI            = 0x260301
 Info                            = 0x0

CONNECT_B3_ACTIVE_IND ID=002 #0x1858 LEN=0013
 Controller/PLCI/NCCI            = 0x260301
 NCPI                            = default

CONNECT_B3_ACTIVE_RESP ID=002 #0x1858 LEN=0012
 Controller/PLCI/NCCI            = 0x260301

-- CAPI queue frame:[ TYPE: Control (4) SUBCLASS: Answer (4) ] [contr1#01]
   -- CAPI/contr1#01/103-11 answered CAPI/contr1#02/123-10
 == contr1#02: Requested Indication-STOP for CAPI/contr1#02/123-10
      > CAPI devicestate requested for contr1#01/103

*CLI> INFO_IND ID=002 #0x3530 LEN=0036
 Controller/PLCI/NCCI            = 0x301
 InfoNumber                      = 0x1c
InfoElement = <91 a1 12 02 01>t<02 01 22>0<0a a1 05>0<03 02 01 00 82 01 01>

INFO_RESP ID=002 #0x3530 LEN=0012
 Controller/PLCI/NCCI            = 0x301

   -- contr1#01: info element FACILITY
INFO_IND ID=002 #0x3531 LEN=0017
 Controller/PLCI/NCCI            = 0x301
 InfoNumber                      = 0x1e
 InfoElement                     = <81 88>

INFO_RESP ID=002 #0x3531 LEN=0012
 Controller/PLCI/NCCI            = 0x301

   -- contr1#01: info element PI 81 88
      > contr1#01: In-band information available
INFO_IND ID=002 #0x3532 LEN=0017
 Controller/PLCI/NCCI            = 0x301
 InfoNumber                      = 0x8
 InfoElement                     = <80 90>

INFO_RESP ID=002 #0x3532 LEN=0012
 Controller/PLCI/NCCI            = 0x301

   -- contr1#01: info element CAUSE 80 90
INFO_IND ID=002 #0x3533 LEN=0015
 Controller/PLCI/NCCI            = 0x301
 InfoNumber                      = 0x8045
 InfoElement                     = default

INFO_RESP ID=002 #0x3533 LEN=0012
 Controller/PLCI/NCCI            = 0x301

   -- contr1#01: info element DISCONNECT
   -- contr1#01: Disconnect case 1
-- CAPI queue frame:[ TYPE: Control (4) SUBCLASS: Hangup (1) ] [contr1#01]
 == contr1#01: CAPI Hangingup for PLCI=0x301 in state 2
   -- contr1#01: activehangingup (cause=16) for PLCI=0x301
DISCONNECT_B3_REQ ID=002 #0x31d3 LEN=0013
 Controller/PLCI/NCCI            = 0x260301
 NCPI                            = default

== Spawn extension (standardtelephonique, 103, 2) exited non-zero on 'CAPI/contr1#02/123-10'
 == contr1#02: CAPI Hangingup for PLCI=0x401 in state 2
   -- contr1#02: activehangingup (cause=16) for PLCI=0x401
DISCONNECT_B3_REQ ID=002 #0x31d4 LEN=0013
 Controller/PLCI/NCCI            = 0x250401
 NCPI                            = default

      > CAPI devicestate requested for contr1#01/103
      > CAPI devicestate requested for contr1#01/103
      > CAPI devicestate requested for contr1#02/123
      > CAPI devicestate requested for contr1#02/123
DISCONNECT_B3_CONF ID=002 #0x31d3 LEN=0014
 Controller/PLCI/NCCI            = 0x260301
 Info                            = 0x0

DISCONNECT_B3_CONF ID=002 #0x31d4 LEN=0014
 Controller/PLCI/NCCI            = 0x250401
 Info                            = 0x0

DISCONNECT_B3_IND ID=002 #0x3535 LEN=0015
 Controller/PLCI/NCCI            = 0x260301
 Reason_B3                       = 0x0
 NCPI                            = default

DISCONNECT_B3_RESP ID=002 #0x3535 LEN=0012
 Controller/PLCI/NCCI            = 0x260301

DISCONNECT_REQ ID=002 #0x31d5 LEN=0013
 Controller/PLCI/NCCI            = 0x301
 AdditionalInfo                  = default

DISCONNECT_B3_IND ID=002 #0x3536 LEN=0015
 Controller/PLCI/NCCI            = 0x250401
 Reason_B3                       = 0x0
 NCPI                            = default

DISCONNECT_B3_RESP ID=002 #0x3536 LEN=0012
 Controller/PLCI/NCCI            = 0x250401

DISCONNECT_REQ ID=002 #0x31d6 LEN=0013
 Controller/PLCI/NCCI            = 0x401
 AdditionalInfo                  = default

DISCONNECT_CONF ID=002 #0x31d5 LEN=0014
 Controller/PLCI/NCCI            = 0x301
 Info                            = 0x0

INFO_IND ID=002 #0x3537 LEN=0015
 Controller/PLCI/NCCI            = 0x301
 InfoNumber                      = 0x805a
 InfoElement                     = default

INFO_RESP ID=002 #0x3537 LEN=0012
 Controller/PLCI/NCCI            = 0x301

   -- contr1#01: info element RELEASE COMPLETE
DISCONNECT_IND ID=002 #0x3539 LEN=0014
 Controller/PLCI/NCCI            = 0x301
 Reason                          = 0x3490

DISCONNECT_RESP ID=002 #0x3539 LEN=0012
 Controller/PLCI/NCCI            = 0x301

      > contr1#01: CAPI INFO 0x3490: Normal call clearing
 == contr1#01: Interface cleanup PLCI=0x301
DISCONNECT_CONF ID=002 #0x31d6 LEN=0014
 Controller/PLCI/NCCI            = 0x401
 Info                            = 0x0

INFO_IND ID=002 #0x353a LEN=0036
 Controller/PLCI/NCCI            = 0x401
 InfoNumber                      = 0x1c
InfoElement = <91 a1 12 02 01>u<02 01 22>0<0a a1 05>0<03 02 01 00 82 01 01>

INFO_RESP ID=002 #0x353a LEN=0012
 Controller/PLCI/NCCI            = 0x401

   -- contr1#02: info element FACILITY
INFO_IND ID=002 #0x353b LEN=0017
 Controller/PLCI/NCCI            = 0x401
 InfoNumber                      = 0x8
 InfoElement                     = <80 90>

INFO_RESP ID=002 #0x353b LEN=0012
 Controller/PLCI/NCCI            = 0x401

   -- contr1#02: info element CAUSE 80 90
INFO_IND ID=002 #0x353c LEN=0015
 Controller/PLCI/NCCI            = 0x401
 InfoNumber                      = 0x804d
 InfoElement                     = default

INFO_RESP ID=002 #0x353c LEN=0012
 Controller/PLCI/NCCI            = 0x401

   -- contr1#02: info element RELEASE
DISCONNECT_IND ID=002 #0x353e LEN=0014
 Controller/PLCI/NCCI            = 0x401
 Reason                          = 0x3490

DISCONNECT_RESP ID=002 #0x353e LEN=0012
 Controller/PLCI/NCCI            = 0x401

      > contr1#02: CAPI INFO 0x3490: Normal call clearing
 == contr1#02: Interface cleanup PLCI=0x401

_______________________________________________

Sign up now for AstriCon 2007!  September 25-28th.  http://www.astricon.net/ 

--Bandwidth and Colocation Provided by http://www.api-digital.com--

asterisk-users mailing list
To UNSUBSCRIBE or update options visit:
   http://lists.digium.com/mailman/listinfo/asterisk-users

Reply via email to