To recap: T100P card wouldn't sync with the telco using line side clocking ( span=1,1,0.........)
Had to use internal clocking (span=1,0,0.......) zttool showed Tx/Rx Levels as 0/ 1 For the grins of it I replaced the T100P card with another newer card from inventory. This newer card has the same rev on the ASIC / FPGA but doesn't have any of the various jumper headers installed on the board. Set clocking to line side sync=1,1,0...... Poof, card comes up, span comes up. zttool now shows Tx/Rx Levels as 0/ 0 No other changes have been made to the various configs on the system. It seems in the end that this was some strange hardware failure on the T100P card. : _______________________________________________ Asterisk-Users mailing list [EMAIL PROTECTED] http://lists.digium.com/mailman/listinfo/asterisk-users To UNSUBSCRIBE or update options visit: http://lists.digium.com/mailman/listinfo/asterisk-users