Hi, After upgrading to DAHDI 2.4.0 from Zaptel, I noticed a lot of HDLC errors on my console: [Nov 27 01:15:09] NOTICE[2743] chan_dahdi.c: PRI got event: HDLC Bad FCS (8) on Primary D-channel of span 1 [Nov 27 01:15:09] NOTICE[2743] chan_dahdi.c: PRI got event: HDLC Abort (6) on Primary D-channel of span 1
These errors prevented calls from being made and received on my PRI spans. This seems similar to bug 15498: https://issues.asterisk.org/view.php?id=15498 Which says this was fixed in 2.2...so maybe it got back into 2.4? I can get rid of the errors by disabling the mg2 echo canceler in /etc/dadhi/system.conf. The PRI card I'm using is a Digium TE122. I'd prefer not having to run with the echo canceler off of course... [1] active=yes alarms=OK description=Wildcard TE122 Card 0 name=WCT1/0 manufacturer=Digium devicetype=Wildcard TE122 location=PCI Bus 03 Slot 03 basechan=1 totchans=24 irq=35 type=digital-T1 syncsrc=1 lbo=0 db (CSU)/0-133 feet (DSX-1) coding_opts=B8ZS,AMI framing_opts=ESF,D4 coding=B8ZS framing=ESF Thanks. -- James -- _____________________________________________________________________ -- Bandwidth and Colocation Provided by http://www.api-digital.com -- New to Asterisk? Join us for a live introductory webinar every Thurs: http://www.asterisk.org/hello asterisk-users mailing list To UNSUBSCRIBE or update options visit: http://lists.digium.com/mailman/listinfo/asterisk-users