On Fri, May 27, 2011 at 08:57:15PM +0000, satish patel wrote: > > You mean say > > 0=Slave (Use PSTN clock) > 1=Master(generate Internal clock) > > So best option is 0 for all span if you connected on PSTN right ?
Not really. Looking in system.conf.sample in dahdi-tools [1] Choose 1 to make the equipment at the far end of the E1/T1/BRI link the preferred source of the master clock. Choose 2 to make it the second choice for the master clock, if the first choice port fails (the far end dies, a cable breaks, or whatever). Choose 3 to make a port the third choice, and so on. If you have, say, 2 ports connected to the PSTN, mark those as 1 and 2. The number used for each port should be different. If you choose 0, the port will never be used as a source of timing. This is appropriate when you know the far end should always be a slave to you. If the port is connected to a channel bank, for example, you should always be its master. Likewise, BRI TE ports should always be configured as a slave. Any number of ports can be marked as 0. [1] http://svn.asterisk.org/view/dahdi/tools/trunk/system.conf.sample?view=co -- Shaun Ruffell Digium, Inc. | Linux Kernel Developer 445 Jan Davis Drive NW - Huntsville, AL 35806 - USA Check us out at: www.digium.com & www.asterisk.org -- _____________________________________________________________________ -- Bandwidth and Colocation Provided by http://www.api-digital.com -- New to Asterisk? Join us for a live introductory webinar every Thurs: http://www.asterisk.org/hello asterisk-users mailing list To UNSUBSCRIBE or update options visit: http://lists.digium.com/mailman/listinfo/asterisk-users