On Thu, Dec 15, 2011 at 11:05 AM, Vieri <[email protected]> wrote: > Hi, > > I have a new Digium TE205P 2-span E1 card I just installed on a server. > > As soon as I boot the machine, the card's leds flash red (ports 1 and 2) - > even when in the BIOS. > > That's not good, right? > > I don't have another machine to test at the moment but would like to know > what to expect. > I have several single-span E1 cards and when the machine boots, their leds > are off until the kernel module is loaded. > > What could be the problem with my TE205P? Could it be damaged (brand new) or > is it more likely to be a PCI-BIOS issue? > > Thanks, > > Vieri
That is normal expected behavior. The card is in a red alarm state that just means there is no link. Its fine. -- ~ Andrew "lathama" Latham [email protected] http://lathama.net ~ -- _____________________________________________________________________ -- Bandwidth and Colocation Provided by http://www.api-digital.com -- New to Asterisk? Join us for a live introductory webinar every Thurs: http://www.asterisk.org/hello asterisk-users mailing list To UNSUBSCRIBE or update options visit: http://lists.digium.com/mailman/listinfo/asterisk-users