have a e100p card that I’ve configured and got running under asterisk in the uk using Telewest (They use a Nortel switch).  But when I try to plug into Kingston (They use a SystemX switch) with exactly the same settings it doesn’t work.

 

I’ve confirmed with the engineers that I’ve got the settings correct, they say their equipment is claiming I’ve not got anything plugged in.

 

Zaptel.conf

 

span=1,1,0,ccs,hdb3,crc4

bchan=1-15,17-31

dchan=16

 

Zapata.conf

 

switchtype=euroisdn

pridialplan=unknown

signalling=pri_cpe

channel => 1-15

channel => 17-31

 

zttool shows all ok.

 

What happens when using pri debug span 1 is I get

 

-- Making new call for cr 32768

> Protocol Discriminator: Q.931 (8)  len=13

> Call Ref: len= 2 (reference 0/0x0) (Originator)

> Message type: RESTART (70)

> Channel ID (len= 5) [ Ext: 1  IntID: Implicit, PRI Spare: 0, Exclusive Dchan:

0

>                        ChanSel: Reserved

>                       Ext: 1  Coding: 0   Number Specified   Channel Type: 3

>                       Ext: 1  Channel: 1 ]

> Restart Indentifier: [ Ext: 1  Spare: 0  Resetting Indicated Channel (0) ]

Urgent handler

< Protocol Discriminator: Q.931 (8)  len=12

< Call Ref: len= 2 (reference 32768/0x8000) (Terminator)

< Message type: STATUS (125)

< Cause (len= 2) [ Ext: 1  Coding: CCITT (ITU) standard (0) 0: 0   Location: Pub

lic network serving the local user (2)

<                  Ext: 1  Cause: Unknown (82), class = Invalid message (5) ]

< Call State (len= 1) [ Ext: 0  Coding: CCITT (ITU) standard (0) Call state: Nul

l (0)

-- Processing IE 8 (Cause)

-- Processing IE 20 (Call State)

 

 

Any Ideas?

 

 

Reply via email to