Hello,
 
I'm trying to connect two * boxen with pri-signalling over TDMoE, but both boxes give me different error messages, wenn I connect them.
 
My configurations and the error message of both boxes:
 
 
-- Box A with Digium-card
 
Zaptel:
 
loadzone=us
defaultzone=us
 
span=1,1,0,ccs,hdb3,crc4
bchan=1-15,17-31
dchan=16
fxoks=32-35
 
dynamic=eth,eth1/00:E0:7D:70:C2:ED,24,0
bchan=36-58
dchan=59
 
 
Zapata for TDMoE:
 
group=3
context=fromoutside
signalling=pri_net
switchtype=euroisdn
callerid="From Outside" <00>
channel => 36-58
 
 
/proc/zaptel/3:
 
Span 3: ZTD/eth/eth1/00:E0:7D:70:C2:ED "Dynamic 'eth' span at 'eth1/00:E0:7D:70:C2:ED'"
 
          36 ZTD/eth/eth1/00:E0:7D:70:C2:ED/1 ClearChannel (In use)
          37 ZTD/eth/eth1/00:E0:7D:70:C2:ED/2 ClearChannel (In use)
          38 ZTD/eth/eth1/00:E0:7D:70:C2:ED/3 ClearChannel (In use)
          39 ZTD/eth/eth1/00:E0:7D:70:C2:ED/4 ClearChannel (In use)
          40 ZTD/eth/eth1/00:E0:7D:70:C2:ED/5 ClearChannel (In use)
          41 ZTD/eth/eth1/00:E0:7D:70:C2:ED/6 ClearChannel (In use)
          42 ZTD/eth/eth1/00:E0:7D:70:C2:ED/7 ClearChannel (In use)
          43 ZTD/eth/eth1/00:E0:7D:70:C2:ED/8 ClearChannel (In use)
          44 ZTD/eth/eth1/00:E0:7D:70:C2:ED/9 ClearChannel (In use)
          45 ZTD/eth/eth1/00:E0:7D:70:C2:ED/10 ClearChannel (In use)
          46 ZTD/eth/eth1/00:E0:7D:70:C2:ED/11 ClearChannel (In use)
          47 ZTD/eth/eth1/00:E0:7D:70:C2:ED/12 ClearChannel (In use)
          48 ZTD/eth/eth1/00:E0:7D:70:C2:ED/13 ClearChannel (In use)
          49 ZTD/eth/eth1/00:E0:7D:70:C2:ED/14 ClearChannel (In use)
          50 ZTD/eth/eth1/00:E0:7D:70:C2:ED/15 ClearChannel (In use)
          51 ZTD/eth/eth1/00:E0:7D:70:C2:ED/16 ClearChannel (In use)
          52 ZTD/eth/eth1/00:E0:7D:70:C2:ED/17 ClearChannel (In use)
          53 ZTD/eth/eth1/00:E0:7D:70:C2:ED/18 ClearChannel (In use)
          54 ZTD/eth/eth1/00:E0:7D:70:C2:ED/19 ClearChannel (In use)
          55 ZTD/eth/eth1/00:E0:7D:70:C2:ED/20 ClearChannel (In use)
          56 ZTD/eth/eth1/00:E0:7D:70:C2:ED/21 ClearChannel (In use)
          57 ZTD/eth/eth1/00:E0:7D:70:C2:ED/22 ClearChannel (In use)
          58 ZTD/eth/eth1/00:E0:7D:70:C2:ED/23 ClearChannel (In use)
          59 ZTD/eth/eth1/00:E0:7D:70:C2:ED/24 HDLCFCS (In use)
 
 
Error message:
 
Mar 12 09:48:05 WARNING[114696]: chan_zap.c:5944 zt_pri_error: PRI: Read on 68 failed: Unknown error 500
 
 
-- Box B
 
Zaptel:
 
loadzone = us
defaultzone=us
 
dynamic=eth,eth1/00:D0:B7:A0:E9:80,24,1
bchan=1-23
dchan=24
 
 
Zapata:

context=home
switchtype=euroisdn
signalling=pri_cpe
channel => 1-23
 
/proc/zaptel/3:
 
Span 1: ZTD/eth/eth1/00:D0:B7:A0:E9:80 "Dynamic 'eth' span at 'eth1/00:D0:B7:A0:E9:80'"
 
           1 ZTD/eth/eth1/00:D0:B7:A0:E9:80/1 ClearChannel (In use)
           2 ZTD/eth/eth1/00:D0:B7:A0:E9:80/2 ClearChannel (In use)
           3 ZTD/eth/eth1/00:D0:B7:A0:E9:80/3 ClearChannel (In use)
           4 ZTD/eth/eth1/00:D0:B7:A0:E9:80/4 ClearChannel (In use)
           5 ZTD/eth/eth1/00:D0:B7:A0:E9:80/5 ClearChannel (In use)
           6 ZTD/eth/eth1/00:D0:B7:A0:E9:80/6 ClearChannel (In use)
           7 ZTD/eth/eth1/00:D0:B7:A0:E9:80/7 ClearChannel (In use)
           8 ZTD/eth/eth1/00:D0:B7:A0:E9:80/8 ClearChannel (In use)
           9 ZTD/eth/eth1/00:D0:B7:A0:E9:80/9 ClearChannel (In use)
          10 ZTD/eth/eth1/00:D0:B7:A0:E9:80/10 ClearChannel (In use)
          11 ZTD/eth/eth1/00:D0:B7:A0:E9:80/11 ClearChannel (In use)
          12 ZTD/eth/eth1/00:D0:B7:A0:E9:80/12 ClearChannel (In use)
          13 ZTD/eth/eth1/00:D0:B7:A0:E9:80/13 ClearChannel (In use)
          14 ZTD/eth/eth1/00:D0:B7:A0:E9:80/14 ClearChannel (In use)
          15 ZTD/eth/eth1/00:D0:B7:A0:E9:80/15 ClearChannel (In use)
          16 ZTD/eth/eth1/00:D0:B7:A0:E9:80/16 ClearChannel (In use)
          17 ZTD/eth/eth1/00:D0:B7:A0:E9:80/17 ClearChannel (In use)
          18 ZTD/eth/eth1/00:D0:B7:A0:E9:80/18 ClearChannel (In use)
          19 ZTD/eth/eth1/00:D0:B7:A0:E9:80/19 ClearChannel (In use)
          20 ZTD/eth/eth1/00:D0:B7:A0:E9:80/20 ClearChannel (In use)
          21 ZTD/eth/eth1/00:D0:B7:A0:E9:80/21 ClearChannel (In use)
          22 ZTD/eth/eth1/00:D0:B7:A0:E9:80/22 ClearChannel (In use)
          23 ZTD/eth/eth1/00:D0:B7:A0:E9:80/23 ClearChannel (In use)
          24 ZTD/eth/eth1/00:D0:B7:A0:E9:80/24 HDLCFCS (In use)
 
 
Error message:
 
Mar 12 09:31:37 WARNING[114696]: chan_zap.c:5967 zt_pri_error: PRI: !! Got S-frame while link down
 
 
Have someone had the same problem with TDMoE an can help me to solve this problem?
 