I'm not certain I understand your question, however: If you have one four wire E&M trunk interface then you can only handle one call over it at a time. E&M is a handshaking protocol, not a multiplexing protocol (such as the protocols used by T1 circuits, which give 24 channels on one pair).
Hope that helps. Kris Boutilier Information Systems Coordinator Sunshine Coast Regional District -----Original Message----- From: muhumuza brian [mailto:[EMAIL PROTECTED] Sent: August 30, 2004 1:56 PM To: [EMAIL PROTECTED] Subject: [Asterisk-Users] number of simultaneous calls with E&M Hullo over there. i'm trying to link an asterisk box with a legacy PBX system with a four wire trunk line. the legacy PBX has 21 analog phones connected to it and i would like to route calls to another site via the asterisk box. i would like to use E&M signaling over this line. my question is how many simultaneous calls can you have over this line with E&M signaling. is there a better way of doing this apart from using T1? _______________________________________________ Asterisk-Users mailing list [EMAIL PROTECTED] http://lists.digium.com/mailman/listinfo/asterisk-users To UNSUBSCRIBE or update options visit: http://lists.digium.com/mailman/listinfo/asterisk-users