Hello, About every 2 or 3 days I notice in the messages log file:
Dec 17 08:39:27 WARNING[1220]: Detected alarm on channel 2: Red Alarm Dec 17 08:39:27 WARNING[1220]: Detected alarm on channel 3: Red Alarm Dec 17 08:39:27 WARNING[1220]: Detected alarm on channel 4: Red Alarm Dec 17 08:39:27 WARNING[1220]: Detected alarm on channel 5: Red Alarm Dec 17 08:39:27 WARNING[1220]: Detected alarm on channel 6: Red Alarm Dec 17 08:39:32 NOTICE[1220]: Alarm cleared on channel 2 Dec 17 08:39:32 NOTICE[1220]: Alarm cleared on channel 3 Dec 17 08:39:32 NOTICE[1220]: Alarm cleared on channel 4 Dec 17 08:39:32 NOTICE[1220]: Alarm cleared on channel 5 Dec 17 08:39:32 NOTICE[1220]: Alarm cleared on channel 6 Every occurance of this problem lasts specifically for 5 seconds. After the 5 seconds, the alarm is cleared. This is occurring with the latest stable version, and occurred with a September CVS version. The hardware is a Digium T100P connected to an Adtran Total Access 750. Is anyone else seeing this problem? Is it possible it is a bug? Thanks, - Brent _______________________________________________ Asterisk-Users mailing list [EMAIL PROTECTED] http://lists.digium.com/mailman/listinfo/asterisk-users To UNSUBSCRIBE or update options visit: http://lists.digium.com/mailman/listinfo/asterisk-users