I have a couple of small machines (home PBX) and run a (tiny) USB APC UPS (nice set of TLA's!)...and love it. Serial ports are so 90's! :-> I am running: Debian Linux X100P FXO card ...and apcupsd: http://www2.apcupsd.com/ (on debian "apt-get install apcupsd")
I like it because it can slave 1 (in my case) or more machines to the apcupsd...so they all gracefully shut down when the UPS is on it's last leg...and power back up (via BIOS settings) when power returns. I have it (apcupsd) setup to email my cell phone when it goes on battery, shuts down or power returns...cute. I looked into this daemon because friends of mine who work under SLA's with big machines and BIG APC UPS's use it and are happy...can't beat that with a stick.
I hope that helps, Todd
PS Sample output:
Wacksides:/# apcaccess APC : 001,034,0858 DATE : Mon Jan 03 23:37:59 PST 2005 HOSTNAME : Wacksides RELEASE : 3.10.15 VERSION : 3.10.15 (04 August 2004) debian UPSNAME : WACKUPS CABLE : USB Cable MODEL : Back-UPS ES 350 UPSMODE : ShareUPS Master STARTTIME: Wed Dec 29 11:11:15 PST 2004 SHARE : ShareUPS STATUS : ONLINE SLAVEDOWN LINEV : 120.0 Volts LOADPCT : 39.0 Percent Load Capacity BCHARGE : 100.0 Percent TIMELEFT : 12.5 Minutes MBATTCHG : 5 Percent MINTIMEL : 3 Minutes MAXTIME : 0 Seconds LOTRANS : 088.0 Volts HITRANS : 138.0 Volts ALARMDEL : Low Battery BATTV : 13.5 Volts NUMXFERS : 0 TONBATT : 0 seconds CUMONBATT: 0 seconds XOFFBATT : N/A STATFLAG : 0x02000808 Status Flag MANDATE : 2004-01-30 SERIALNO : AB0405146301 BATTDATE : 2000-00-00 NOMBATTV : 12.0 FIRMWARE : 00.e5.D USB FW:e5 APCMODEL : Back-UPS ES 350 END APC : Mon Jan 03 23:38:02 PST 2005
----- Original Message ----- From: "Steven Critchfield" <[EMAIL PROTECTED]>
To: "Asterisk Users Mailing List - Non-Commercial Discussion"
<[email protected]>
Sent: Monday, January 03, 2005 2:18 PM
Subject: Re: [Asterisk-Users] UPS - a little OT
On Mon, 2005-01-03 at 23:32 +0200, Shoval Tomer wrote:Hi all.
Can someone recommend a good UPS for using with an * machine that provides some linux tested software to do managed shutdown in case of power loss?
APC -- Steven Critchfield <[EMAIL PROTECTED]>
_______________________________________________ Asterisk-Users mailing list [email protected] http://lists.digium.com/mailman/listinfo/asterisk-users To UNSUBSCRIBE or update options visit: http://lists.digium.com/mailman/listinfo/asterisk-users
_______________________________________________ Asterisk-Users mailing list [email protected] http://lists.digium.com/mailman/listinfo/asterisk-users To UNSUBSCRIBE or update options visit: http://lists.digium.com/mailman/listinfo/asterisk-users