Hi all,
We have been fighting with telco for a entire week. Today they came here with a LITE3000 to analyze what is going on.
When I configure zaptel with no external clock, E1 gets aligned/synchronized with bit rate in 2048000 bps, both me and telco.
span=4,0,0,ccs,hdb3,crc4
But when I configure span4 to get clock source from telco they become unsynchronized. TElco bit rate stays in 2048000 bps, but asterisk stays on 2048443 pbs!!
span=4,1,0,ccs,hdb3,crc4
Telco1 (Intelig) send alarms and I do not sync to then.
I have another PRI circuit used for data connections from Telco2 and I used it for testing.
Telco2 (Telemar) do not send alarms and I sync to then.
Does anybody have some idea about what is happening?
Regards []s -- Alex G Robertson NOC - Microlink
_______________________________________________ Asterisk-Users mailing list [email protected] http://lists.digium.com/mailman/listinfo/asterisk-users To UNSUBSCRIBE or update options visit: http://lists.digium.com/mailman/listinfo/asterisk-users
