I am trying to use TE110p card for Euro ISDN with Ericsson AMS switch. I consistently get one of the following errors:
PRI got event: HDLC Abort (6) on Primary D-channel of span 1 or PRI got event: HDLC Bad FCS (8) on Primary D-channel of span 1 My zaptel.conf file: -------------------------------- span=1,0,0,ccs,hdb3,crc4 bchan=1-15,17-31 dchan=16 loadzone=us defaultzone=us -------------------------------- My partner and I have tried to find answer on google, IRC and even digium tech support but no luck so far :-( I observe the same behavior on FC3 as well as RH9, and on different hardware too. One of them is Intel Motherboard with 3 GHz P4 processor (FC3), the other is Supermicro with 2.4GHz Dual Xeon processor (RH9). Surprisingly, a similar machine with Supermicro motherboard works very well with TE405p card. I checked the interrupts etc. and there is no shared interrupt with the card. Hence I suspect the issue is at the signaling level or with the card's driver rather than some interrupts getting lost. I could be completely wrong though. Any help will be greatly appreciated. Thanks, -- jt _______________________________________________ Asterisk-Users mailing list Asterisk-Users@lists.digium.com http://lists.digium.com/mailman/listinfo/asterisk-users To UNSUBSCRIBE or update options visit: http://lists.digium.com/mailman/listinfo/asterisk-users