Hello,
        Haven't had a chance to test this configuration yet, so I can't 
really answer my own question, but wanted to get a couple of eyeballs to 
look at it and verify that I'm going to get the behavior that I expect out 
of it. Basically, I have a TE405P w/ 3 PRI to the Telco and one going to a 
legacy PBX, all speaking NI-2 (National ISDN 2). I need to use "pri_cpe" 
w/ the Telco and "pri_net" for the PBX, and I want them in different 
groups. I hacked the following up last night, while falling asleep, and 
I'm pretty sure it will do what I want, but I'd like a second opinion.

; Zapata telephony interface
;
; Configuration file

[channels]
; Inbound PRI from Telco
context=inbound
switchtype=national
signalling=pri_cpe
group=1    
channel => 1-23,25-47,49-71

; Outbound PRI to PBX
context=pbx
switchtype = national
signalling = pri_net
group = 2
channel => 73-95

Thanks..

-- 
    Vice President of N2Net, a New Age Consulting Service, Inc. Company
         http://www.n2net.net Where everything clicks into place!
                             KP-216-121-ST