Steve Prior wrote:

I just got a refurb Sipura SPA-2000 and was able to assign it an IP
address with DHCP and ping the device, but then I ran the firmware upgrade utility to bring it up to spa2k-2.0.13g which seemed to
work just fine, but after it rebooted I cannot connect to its
webserver for configuration. I can still ping the unit. When
I use the built in voice menu it reads back the right IP address,
webserver port, and claims the webserver is enabled, but I can't
connect to port 80 on the device and running the firmware upgrade
utility says that it cannot connect to the unit either.

Sounds like you got the one we just sent back to Sipura a couple weeks ago. Try to update the firmware again; if that fails I'd suggesting contacting Sipura for an RMA.


The one we had seemed heat induced. It would work fine for a few minutes and then just die (but always still responded to pings). No calls and no web interface would work until it was unplugged and cooled down.