Rich Adamson wrote:
The *proper* way to see it is with a voltmeter. your off-hook voltage should be between roughly -5 and -15 Volts DC. CPD should either disconnect the battery (0V) or reverse the battery (-5-15VDC) briefly upon remote party hangup.


Just to add to Andrew's comment above, the majority of US analog pstn
lines will disconnect battery for about 400 milliseconds. However,
a fair number of non-US countries either provide no disconnect supervision, or use some other approach (eg, tones).

Thanks for your suggestions. Let me check with my provider if the network supports CPD.

raj