On Sunday 12 June 2005 10:21, Michael Di Martino wrote:
> I thinking it is a timing issue, but i an not sure how to test.
> What type of PRI signaling and timing do u use to connect to your MICS.
> and yes my 0x32 is a MICS.

You don't go in and out of red alarm on a timing issue.  Check the cabling, 
I've seen cables that look just fine until you wiggle them.  The MICS should 
give you som ekind of indication too in its event logs.

I have the zaptel card NOT syncing to the MICS, since hte MICS is designed to 
sync to the telco (it can be a itming master but that's not it's normal mode 
of operation).

-A.