Hi All,

On Fri, Jul 1, 2016 at 9:07 PM, Vasanthakumar Thiagarajan
<[email protected]> wrote:
> As hw cycle counters in QCA4019 wraparound independantly in QCA4019
> it is possible cycle counter and rx clear counter would wraparound
> at the same time. Current logic assumes only one of the counters
> would wraparound at anytime. Fix this by moving 'else' part to
> another 'if'.
>
> Fixes: 8e100354a98 ("ath10k: fix cycle counter wraparound handling for 
> QCA4019")
> Signed-off-by: Vasanthakumar Thiagarajan <[email protected]>

Looks right to me.

Reviewed-by: Julian Calaby <[email protected]>

Thanks,

-- 
Julian Calaby

Email: [email protected]
Profile: http://www.google.com/profiles/julian.calaby/

_______________________________________________
ath10k mailing list
[email protected]
http://lists.infradead.org/mailman/listinfo/ath10k

Reply via email to