SBGK wrote: > With spdif out I was using a period count of 4. Setting the buffer time > to 999999999 gave period and buffer sizes of 1024/4096 for all sample > rates. > > With lower buffer time the buffer size and period size would be smaller. > The exact buffer cut off that allows this behaviour is somewhere between > 100000 and 999999999. >
Let's be clear on this - for period count of 4, with the TXRX spdif driver there is no point setting the buffer time above 100000 as at 44.1 this gives a period time of 23219 which is is already limited by the buffer size. ------------------------------------------------------------------------ Triode's Profile: http://forums.slimdevices.com/member.php?userid=17 View this thread: http://forums.slimdevices.com/showthread.php?t=94855 _______________________________________________ audiophiles mailing list [email protected] http://lists.slimdevices.com/mailman/listinfo/audiophiles