On Saturday 03 June 2006 20:14, Rolf Magnus wrote: > On Saturday 03 June 2006 07:51, Dmitry K. wrote: [...] > The datasheet says it quite clearly: > > "If the ADC is enabled, a conversion starts automatically when this mode is > entered."
Alas, you are right. > This doesn't depend on auto trigger source or the ADC interrupt settings. > The solution is to simply switch the ADC off (ADEN=0). Unfortunately, thus the internal Vref is switched off (regardless of ADMUX). At repeated inclusion, except for increased time of conversion (25 steps), it is necessary to wait for transition to a stady state an Vref voltage (with external capasitor) and on additional schemes which use a Vref. > Well, you can use a timer as auto trigger source. Yes, in result there is a mixture of unregular conversions. And in case of period about 1.5 ... 2 of conversion time the result is vary bad. (Delete 'sleep' --> all OK.) Im am not understand Atmel's idea to merge Auto Trigger mode with Auto Start for each 'sleep' instruction. Thanks, Dmitry. _______________________________________________ AVR-chat mailing list [email protected] http://lists.nongnu.org/mailman/listinfo/avr-chat