Apologies for the second reply, but this may be a bit more of a
important question surrounding this issue. I have a multi-threaded
application, with each thread creating and using various Stubs
(sometimes multiple stubs to access various parts of the webservice). If
each Stub is creating its own HTTP server, how have I never run into an
issue like this before? It seems that each thread and each stub in that
thread would be trying to start a server on the same port.
I can set the HTTPConstants.REUSE_HTTP_CLIENT option to true, but it
still seems like I may have some issues.
Is creating a global HttpClient and setting it in each thread (with
HTTPConstants.CACHED_HTTP_CLIENT) the "proper" thing to do?
Thanks again for the good advice!
-Jake
Michele Mazzucco wrote:
On Mon, 2007-04-23 at 11:29 -0400, Jake Goulding wrote:
Thanks Michele!
That did help, but left me with 2.5 questions:
1/ Why does the client need to spawn a web server at all?
Because it uses two separate channels.
1b/ Is it possible to disable this server completely?
Yes, disable the addressing module and use a single channel (i.e.
synchronous communication).
2/ If I create a ConfigurationContext, how do I set what I need to set,
and then how do I use it?
See here (for example)
http://wso2.org/library/87
http://wso2.org/library/585
http://wso2.org/library/290
http://wso2.org/library/209
Michele
Thanks!
Michele Mazzucco wrote:
http://wso2.org/library/165
HTH,
Michele
On Mon, 2007-04-23 at 10:28 -0400, Jake Goulding wrote:
Hey all:
I use axis to connect to a Windows Sharepoint server. Recently, an
installation of our code started returning these errors:
java.net.BindException: Address already in use: connect; nested
exception is:
org.apache.axis2.AxisFault: Address already in use: connect; nested
exception is:
java.net.BindException: Address already in use: connect
What I don't get is how this is possible. Pure client code should not
need to bind to any particular address/port at all. The code generated
from the WSDL shouldn't even have the server-side code generated. Thanks
in advance for any hints / fixes!
-Jake
---------------------------------------------------------------------
To unsubscribe, e-mail: [EMAIL PROTECTED]
For additional commands, e-mail: [EMAIL PROTECTED]
---------------------------------------------------------------------
To unsubscribe, e-mail: [EMAIL PROTECTED]
For additional commands, e-mail: [EMAIL PROTECTED]
---------------------------------------------------------------------
To unsubscribe, e-mail: [EMAIL PROTECTED]
For additional commands, e-mail: [EMAIL PROTECTED]
--
JAKE GOULDING
Software Engineer
[EMAIL PROTECTED]
Vivísimo [Search Done Right™]
1710 Murray Avenue
Pittsburgh, PA 15217 USA
tel: +1.412.422.2499 x105
fax: +1.412.422.2495
vivisimo.com clusty.com
---------------------------------------------------------------------
To unsubscribe, e-mail: [EMAIL PROTECTED]
For additional commands, e-mail: [EMAIL PROTECTED]