This is just for the archives, and for anyone reading to file away in the back 
of their mind for future reference.

I recently installed bacula-fd on a Windows machine here, ran the "estimate" 
test, and all worked fine.  Set up the job, and read my reports the next 
morning.  Well, the next morning, that machine had an error in the report, 
and it said could not connect, no route to host."  But when I telneted to 
port 9102 or ran a job manually, it worked fine.

This had had me stumped for a little while, until we figured it out: the 
system was set to autosuspend, so would no respond at 1 in the morning.  
Setting autosuspend to "never" fixed the problem.  We still shut the display 
and harddrive down automatically, just the system itself never suspends, so 
we can run the backups.

Hope that helps someone.

j----- k-----

-- 
Joshua Kugler
CDE System Administrator
http://distance.uaf.edu/


-------------------------------------------------------