On 13 Sep 2005 at 19:23, Arunav Mandal wrote:

> ----- Original Message ----- 
> From: "Dan Langille" <[EMAIL PROTECTED]>
> To: "Arunav Mandal" <[EMAIL PROTECTED]>
> Cc: <bacula-users@lists.sourceforge.net>
> Sent: Tuesday, September 13, 2005 7:07 PM
> Subject: Re: [Bacula-users] Tape error
> 
> 
> > On 13 Sep 2005 at 19:00, Arunav Mandal wrote:
> >
> >> I have seen errors given below quite often even with new tapes. This
> >> happens mostly when I try to restore files from a tape that has been
> >> recently written and got a Append tag. It restores fine but when it
> >> try to write again this error comes up maybe because the tape media
> >> has moved forward or backwards. I use 1.36.3.
> >>
> >> Error: I canot write on Volume "SDLT010" because:
> >> The number of files mismatch! Volume=303 Catalog=301
> >> 13-Sep 16:32 abc-sd: Marking Volume "SDLT010" in Error in Catalog.
> >
> > I understand this is a known bug, fixed in CVS.
> 
> What happens when I change the error to Append manually will the tape
> be used again? 

Yes.
-- 